Figure 5   Passive Heat Front Discharge Framing Dimensions with Clean Face Finish or Trim Kit

  *   Measurement for Trim Kit = 3-1/2 in. + additional finishing material thickness 

 **   Measurement for without trim kit = 2 in. + additional finishing material thickness.  If discharge opening is greater than   

3 inches wire mesh is required.  See details in the Framing Section.

Framing Dimensions - Passive Heat Front Discharge (PH-FRT) Single-Sided or See-Through

WARNING! Risk of Fire!   

Wire mesh required 

on bottom of discharge opening when discharge 

opening is greater than 3 inches.  Secure mesh to 

top of framing.

A

E

D

C

B

APPLIANCE MAY BE INSTALLED 

OFF OF FLOOR

F

Front Discharge:  Air conveyed into the room through one front discharge slot.

ROOM CEILING

1-1/2 IN. (2 X 4 FRAMING)

2 IN. MIN.

TV

1/2 IN. X 1/2 IN.

WIRE MESH**

CHASE CEILING (REQUIRED)

WIRE MESH**

= PASSIVE HEAT 

   DISCHARGE OPENING

CHASE DETAIL

FRONT DISCHARGE FRAMING DIMENSIONS

A

B

C

D

E

F

TRIM KIT* 

(PH-TRIM)

NO TRIM 

KIT**

Height of 

Discharge

 Opening

Minimum 

Height of 

Discharge 

Opening

Minimum 

Clearance 

to

 Framing

Width of 

Discharge 

Opening

Clearance 

to Top of 

Discharge 

Opening 

from Bottom 

of Appliance

Clearance 

from Bottom 

of Appliance 

to Bottom of 

Discharge 

Opening

Minimum 

Clearance 

Discharge 

Opening to 

Ceiling

MEZZO36-C/ST-C

CRAVE4836-C/ST-C

ECHEL36IN-C/STIN-C

Inches

3-1/2

2

48

36-1/2

74-1/2

72-1/2

51-1/2

millimeters

89

51

1219

927

1892

1842

1308

MEZZO48-C/ST-C

CRAVE6048-C/ST-C

ECHEL48IN-C/STIN-C

Inches

3-1/2

2

48

48-1/2

74-1/2

72-1/2

51-1/2

millimeters

89

51

1219

1232

1892

1842

1308

MEZZO60-C/ST-C

CRAVE7260-C/ST-C

ECHEL60IN-C

Inches

3-1/2

2

48

60-1/2

74-1/2

72-1/2

51-1/2

millimeters

89

51

1219

1537

1892

1842

1308

MEZZO72-C/ST-C

CRAVE8472-C/ST-C

ECHEL72IN-C

Inches

3-1/2

2

67-1/2

72-1/2

94

92

71

millimeters

89

51

1715

1842

2388

2337

1803

Summary of Contents for CRAVE-C Series

Page 1: ...stallation of the Passive Heat system The Passive Heat kit is tested and safe when installed in accordance with this installation manual It is your respon sibility to read all instructions before star...

Page 2: ...RVICE PART NO QTY Register Cover 2560 120 2 Inner Flue Top Service part not available 4 Pull Tool 2600 200 1 Figure 2 Side Discharge Passive Heat Kit Components 2560 120 12 in x 8 in Register Cover Qu...

Page 3: ...ge opening in the same room DRA DRA INTERIOR WALL FLOOR CEILING 36 IN 36 IN 6 IN 18 IN 18 IN PASSIVE HEAT FRONT DISCHARGE OPENING Clearances for front and side discharge installations FIREPLACE CEILIN...

Page 4: ...ed on the top of the framing above the appliance The wire mesh will prevent objects from falling through the opening and onto the top of the appliance The wire mesh may be available at a hardware or h...

Page 5: ...ance 24 1 2 IN ROOM CEILING TV 12 IN MIN 4 IN MIN 1 2 IN X 1 2 IN WIRE MESH Wire mesh required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches o...

Page 6: ...N MIN TV 1 2 IN X 1 2 IN WIRE MESH CHASE CEILING REQUIRED WIRE MESH PASSIVE HEAT DISCHARGE OPENING CHASE DETAIL FRONT DISCHARGE FRAMING DIMENSIONS A B C D E F TRIM KIT PH TRIM NO TRIM KIT Height of Di...

Page 7: ...pening to Ceiling MEZZO36 C ST C CRAVE4836 C ST C ECHEL36IN C STIN C Inches 12 1 4 8 3 4 62 3 4 76 1 2 18 52 millimeters 311 222 1594 1943 457 1321 MEZZO48 C ST C CRAVE6048 C ST C ECHEL48IN C STIN C I...

Page 8: ...48 48 1 2 50 millimeters 51 1219 1232 1270 MEZZO60 C ST C CRAVE7260 C ST C ECHEL60IN C Inches 2 48 60 1 2 50 millimeters 51 1219 1537 1270 MEZZO72 C ST C CRAVE8472 C ST C ECHEL72IN C Inches 2 67 1 2 7...

Page 9: ...igure 10 4 Remove the screws from the heat shield as shown in Figure 14 Quantity and location of screws will vary between models CAUTION Risk of Cuts or Abrasions Wear protective gloves Sheet metal ed...

Page 10: ...13 Pull Tool Inserted Into Slot REMOVE SCREWS REMOVE SCREWS PULL TOOLS PULL TOOLS Figure 15 Remove Heat Shield 9 Side Discharge Only Instructions continue on the following page WARNING Risk of Fire R...

Page 11: ...e are other heat management options available for use with the MEZZO C CRAVE C and ECHELON C models Consult the appliance manual for compatible op tions Only one Passive Heat knockout may be used for...

Reviews: