6
Hearth & Home Technologies • PH-FRT, PH-SIDE Instructions • 2600-970 Rev. H • 4/20
Figure 5 Passive Heat Front Discharge Framing Dimensions with Clean Face Finish or Trim Kit
* Measurement for Trim Kit = 3-1/2 in. + additional finishing material thickness
** Measurement for without trim kit = 2 in. + additional finishing material thickness. If discharge opening is greater than
3 inches wire mesh is required. See details in the Framing Section.
Framing Dimensions - Passive Heat Front Discharge (PH-FRT) Single-Sided or See-Through
WARNING! Risk of Fire!
Wire mesh required
on bottom of discharge opening when discharge
opening is greater than 3 inches. Secure mesh to
top of framing.
A
E
D
C
B
APPLIANCE MAY BE INSTALLED
OFF OF FLOOR
F
Front Discharge: Air conveyed into the room through one front discharge slot.
ROOM CEILING
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
TV
1/2 IN. X 1/2 IN.
WIRE MESH**
CHASE CEILING (REQUIRED)
WIRE MESH**
= PASSIVE HEAT
DISCHARGE OPENING
CHASE DETAIL
FRONT DISCHARGE FRAMING DIMENSIONS
A
B
C
D
E
F
TRIM KIT*
(PH-TRIM)
NO TRIM
KIT**
Height of
Discharge
Opening
Minimum
Height of
Discharge
Opening
Minimum
Clearance
to
Framing
Width of
Discharge
Opening
Clearance
to Top of
Discharge
Opening
from Bottom
of Appliance
Clearance
from Bottom
of Appliance
to Bottom of
Discharge
Opening
Minimum
Clearance
Discharge
Opening to
Ceiling
MEZZO36-C/ST-C
CRAVE4836-C/ST-C
ECHEL36IN-C/STIN-C
Inches
3-1/2
2
48
36-1/2
74-1/2
72-1/2
51-1/2
millimeters
89
51
1219
927
1892
1842
1308
MEZZO48-C/ST-C
CRAVE6048-C/ST-C
ECHEL48IN-C/STIN-C
Inches
3-1/2
2
48
48-1/2
74-1/2
72-1/2
51-1/2
millimeters
89
51
1219
1232
1892
1842
1308
MEZZO60-C/ST-C
CRAVE7260-C/ST-C
ECHEL60IN-C
Inches
3-1/2
2
48
60-1/2
74-1/2
72-1/2
51-1/2
millimeters
89
51
1219
1537
1892
1842
1308
MEZZO72-C/ST-C
CRAVE8472-C/ST-C
ECHEL72IN-C
Inches
3-1/2
2
67-1/2
72-1/2
94
92
71
millimeters
89
51
1715
1842
2388
2337
1803