Hearth & Home Technologies  •  PH-FRT, PH-SIDE Instructions  •  2600-970 Rev. H  •  4/20

Figure 4   Good Faith TV Guidelines   

WARNING! Risk of Fire!   

Wire mesh required on bottom of discharge opening when discharge 

opening is greater than 3 inches.  Secure wire mesh to top of framing.

Good Faith TV Guidelines

Measurement from top edge

of opening to bottom of 

appliance = 24-1/2 IN.

ROOM CEILING

TV

12 IN. MIN.

4 IN. MIN.

1/2 IN. X 1/2 IN.

WIRE MESH*

 * Wire mesh required for front discharge or open top discharge passive heat installations with discharge 

   opening of 3 inches or greater.

Good Faith Guidelines for TV Installations 

Above a MEZZO-C/CRAVE-C/ECHELON-C Fireplace with Passive Heat Option

(Single-Sided Appliance Shown)

FIREPLACE 

OPENING

2 X 4 FRAMING

2 X 4 OR 2 X 6

FRAMING

WIRE MESH*

= PASSIVE HEAT 

   DISCHARGE OPENING

2 IN. MIN.

1-1/2 IN. (2 X 4 FRAMING)

CHASE CEILING - SEE FIGURES 5 AND 6

(FRONT AND SIDE DISCHARGE ONLY)

Summary of Contents for CRAVE-C Series

Page 1: ...stallation of the Passive Heat system The Passive Heat kit is tested and safe when installed in accordance with this installation manual It is your respon sibility to read all instructions before star...

Page 2: ...RVICE PART NO QTY Register Cover 2560 120 2 Inner Flue Top Service part not available 4 Pull Tool 2600 200 1 Figure 2 Side Discharge Passive Heat Kit Components 2560 120 12 in x 8 in Register Cover Qu...

Page 3: ...ge opening in the same room DRA DRA INTERIOR WALL FLOOR CEILING 36 IN 36 IN 6 IN 18 IN 18 IN PASSIVE HEAT FRONT DISCHARGE OPENING Clearances for front and side discharge installations FIREPLACE CEILIN...

Page 4: ...ed on the top of the framing above the appliance The wire mesh will prevent objects from falling through the opening and onto the top of the appliance The wire mesh may be available at a hardware or h...

Page 5: ...ance 24 1 2 IN ROOM CEILING TV 12 IN MIN 4 IN MIN 1 2 IN X 1 2 IN WIRE MESH Wire mesh required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches o...

Page 6: ...N MIN TV 1 2 IN X 1 2 IN WIRE MESH CHASE CEILING REQUIRED WIRE MESH PASSIVE HEAT DISCHARGE OPENING CHASE DETAIL FRONT DISCHARGE FRAMING DIMENSIONS A B C D E F TRIM KIT PH TRIM NO TRIM KIT Height of Di...

Page 7: ...pening to Ceiling MEZZO36 C ST C CRAVE4836 C ST C ECHEL36IN C STIN C Inches 12 1 4 8 3 4 62 3 4 76 1 2 18 52 millimeters 311 222 1594 1943 457 1321 MEZZO48 C ST C CRAVE6048 C ST C ECHEL48IN C STIN C I...

Page 8: ...48 48 1 2 50 millimeters 51 1219 1232 1270 MEZZO60 C ST C CRAVE7260 C ST C ECHEL60IN C Inches 2 48 60 1 2 50 millimeters 51 1219 1537 1270 MEZZO72 C ST C CRAVE8472 C ST C ECHEL72IN C Inches 2 67 1 2 7...

Page 9: ...igure 10 4 Remove the screws from the heat shield as shown in Figure 14 Quantity and location of screws will vary between models CAUTION Risk of Cuts or Abrasions Wear protective gloves Sheet metal ed...

Page 10: ...13 Pull Tool Inserted Into Slot REMOVE SCREWS REMOVE SCREWS PULL TOOLS PULL TOOLS Figure 15 Remove Heat Shield 9 Side Discharge Only Instructions continue on the following page WARNING Risk of Fire R...

Page 11: ...e are other heat management options available for use with the MEZZO C CRAVE C and ECHELON C models Consult the appliance manual for compatible op tions Only one Passive Heat knockout may be used for...

Reviews: