background image

1

Hearth & Home Technologies  •  PH-FRT, PH-SIDE Instructions  •  2600-970 Rev. H  •  4/20

PH-FRT, PH-SIDE

Models: MEZZO-C Series, CRAVE-C Series, ECHELON-C Series

Passive Heat Kit 

Installation Instructions

Leave this manual with party responsible for use 

and operation.

CAUTION! Risk of Cuts, Abrasions or Flying Debris. 

Wear protective gloves and safety glasses during instal-

lation. Sheet metal edges are sharp.

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A barrier designed to reduce the risk of 

burns from the hot viewing glass is provided 

with this appliance and shall be installed for 

the protection of children and other at-risk 

individuals.

CAUTION! Do not install damaged components.

If any parts are missing or damaged, contact your dealer before 

starting installation. 

DO NOT

 install a damaged  kit. 

Introduction

The  Passive Heat (PH-FRT, PH-SIDE) Heat  Manage-

ment System conveys warm air from the fireplace into the 

same room through either a front discharge slot or two 

side discharge heat registers.  Installation of the Passive 

Heat kit must be done in conjunction with the appliance 

installation.  

 

Installation of this kit 

MUST

 be performed by 

a qualified service technician.  

 

WARNING!  Risk of Fire!  DO

 

NOT

 install the Passive 

Heat (PH-FRT or PH-SIDE) Heat Management System 

with models that are not approved. Overheating will oc-

cur.  

The Passive Heat Trim Kit (PHTRIM-XX) is also available 

for installation with the Front Discharge Passive Heat 

systems and must be purchased separately.  Follow in-

structions included with the trim kit to complete installation 

of the Passive Heat system.
The Passive Heat kit is tested and safe when installed in 

accordance with this installation manual. It is your respon-

sibility to read all instructions before starting installation 

and to follow these instructions carefully during installation.
The Passive Heat kit is carefully engineered and must 

be installed only as specified.  If you modify it or any of 

its components you will void the warranty, and you may 

possibly cause a fire hazard. Installation must be done 

according to applicable local, state, provincial, and/or 

national codes.

Table of Contents

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Preparation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Clearances   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Framing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Good Faith TV Guidelines  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Framing Dimensions - Passive Heat Front Discharge (PH-FRT) 

Single-Sided or See-Through . . . . . . . . . . . . . . . . . . . . . . . 6

Framing Dimensions - Passive Heat Side Discharge (PH-SIDE) 

Single-Sided or See-Through . . . . . . . . . . . . . . . . . . . . . . . 7

Framing Dimensions - Passive Heat Open Top Discharge 

  Single-Sided or See-Through . . . . . . . . . . . . . . . . . . . . . . . 8

Installation Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

(Front, Side or Open Top Discharge) . . . . . . . . . . . . . . . . . . . . 9

Install Register Cover - Side Discharge Only   . . . . . . . . . . . . 11

Installation of Passive Heat with Other Optional Heat 

  Management Systems  . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Power Vent Option

If  an optional power vent will be installed in conjunction 

with the Passive Heat Kit (PH-FRT or PH-SIDE), Hearth & 

Home Technologies recommends the PVLP-SLP power vent 

option. If the application does not allow for the PVLP-SLP 

to be used, the PVI-SLP-B may be used.  The PVI-SLP-B 

must be mounted outside the chase due to the higher 

noise level created.  

CAUTION! Risk of Burns! 

•  Appliance MUST be turned off and cooled before kit is 

installed.

•  Shut off gas supply.

Preparation

Plan the location of the appliance.

Determine whether front or side discharge is to be installed 

and follow instructions for the appropriate application.  

Summary of Contents for CRAVE-C Series

Page 1: ...stallation of the Passive Heat system The Passive Heat kit is tested and safe when installed in accordance with this installation manual It is your respon sibility to read all instructions before star...

Page 2: ...RVICE PART NO QTY Register Cover 2560 120 2 Inner Flue Top Service part not available 4 Pull Tool 2600 200 1 Figure 2 Side Discharge Passive Heat Kit Components 2560 120 12 in x 8 in Register Cover Qu...

Page 3: ...ge opening in the same room DRA DRA INTERIOR WALL FLOOR CEILING 36 IN 36 IN 6 IN 18 IN 18 IN PASSIVE HEAT FRONT DISCHARGE OPENING Clearances for front and side discharge installations FIREPLACE CEILIN...

Page 4: ...ed on the top of the framing above the appliance The wire mesh will prevent objects from falling through the opening and onto the top of the appliance The wire mesh may be available at a hardware or h...

Page 5: ...ance 24 1 2 IN ROOM CEILING TV 12 IN MIN 4 IN MIN 1 2 IN X 1 2 IN WIRE MESH Wire mesh required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches o...

Page 6: ...N MIN TV 1 2 IN X 1 2 IN WIRE MESH CHASE CEILING REQUIRED WIRE MESH PASSIVE HEAT DISCHARGE OPENING CHASE DETAIL FRONT DISCHARGE FRAMING DIMENSIONS A B C D E F TRIM KIT PH TRIM NO TRIM KIT Height of Di...

Page 7: ...pening to Ceiling MEZZO36 C ST C CRAVE4836 C ST C ECHEL36IN C STIN C Inches 12 1 4 8 3 4 62 3 4 76 1 2 18 52 millimeters 311 222 1594 1943 457 1321 MEZZO48 C ST C CRAVE6048 C ST C ECHEL48IN C STIN C I...

Page 8: ...48 48 1 2 50 millimeters 51 1219 1232 1270 MEZZO60 C ST C CRAVE7260 C ST C ECHEL60IN C Inches 2 48 60 1 2 50 millimeters 51 1219 1537 1270 MEZZO72 C ST C CRAVE8472 C ST C ECHEL72IN C Inches 2 67 1 2 7...

Page 9: ...igure 10 4 Remove the screws from the heat shield as shown in Figure 14 Quantity and location of screws will vary between models CAUTION Risk of Cuts or Abrasions Wear protective gloves Sheet metal ed...

Page 10: ...13 Pull Tool Inserted Into Slot REMOVE SCREWS REMOVE SCREWS PULL TOOLS PULL TOOLS Figure 15 Remove Heat Shield 9 Side Discharge Only Instructions continue on the following page WARNING Risk of Fire R...

Page 11: ...e are other heat management options available for use with the MEZZO C CRAVE C and ECHELON C models Consult the appliance manual for compatible op tions Only one Passive Heat knockout may be used for...