background image

4

Hearth & Home Technologies  • SMART-BATT-II Remote Control Instructions  •  100-909 Rev. i  •  5/12

Figure 6.  Millivolt with Receiver

Figure 7.  Intermittent Pilot Ignition (IPI) Wiring Diagram

C.  Wiring Intermittent Pilot Ignition (IPI) with Rocker Switch

REMOTE RECEIVER

LEARN

ON/OFF REMOTE SWITCH

PIEZO

RED

WHITE

VALVE

PILOT

THERMOCOUPLE

WIRE

TERMINALS

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GR

N

OR

G

INTERMITTENT

PILOT

IGNITOR

ORG

WHT

VALVE

PIGGYBACK 

ON/OFF SWITCH

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF #1-#5 LOCATIONS

ON THE NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BR

N

BR

N

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

S

I

Summary of Contents for SMART-BATT-II

Page 1: ...two condi tions 1 this device may not cause interference and 2 this device must accept any interference including interfer ence that may cause undesired operation of the device SMART BATT II Remote Control Kits Installation and Operating Instructions INTRODUCTION The remote control system can be operated thermostati cally or manually from the transmitter The system operates on radio frequencies RF...

Page 2: ...URITY CODES and recheck battery position in the remote receiver RECEIVER WIRING INSTRUCTIONS Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appliance and may also damage the remote receiver Make sure the remote receiver switch is in the OFF position Use 18 gauge stranded wires for connections between the terminal wiring block on the millivolt...

Page 3: ...eceiver box see Figure 4 3 WIRE ASSEMBLY PIEZO RED WHITE PILOT THERMOCOUPLE VALVE If your fireplace is wired like Figure 5 remove 3 wires from the valve by unplugging the spade from the valve Install the jumper wire on the terminal on the valve as shown in Figure 6 Then install one of the leads from the receiver onto the valve and the other wire onto the lead from the jumper wire B Wiring Millivol...

Page 4: ... with Rocker Switch REMOTE RECEIVER LEARN ON OFF REMOTE SWITCH PIEZO RED WHITE VALVE PILOT THERMOCOUPLE WIRE TERMINALS IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR ORG WHT VALVE PIGGYBACK ON OFF SWITCH WHITE WIRE CAN BE PLUGGED INTO ANY OF 1 5 LOCATIONS ON THE NEUTRAL SIDE BLACK WIRE CAN BE PLUGGED INTO ANY OF 1 5 LOCATIONS ON THE HOT SIDE BRN BRN PLUG IN GROUND TO FI...

Page 5: ... or wall switch only Take the leads and plug them into wire leads on remote receiver box see Figure 8 ON OFF SLIDE SWITCH BLACK RED BATTERY PACK PIGGYBACK ON OFF SWITCH GRN ORG BROWN BROWN ORANGE WHITE TRANSFORMER 3 VAC PLUG IN GROUND TO FIREPLACE CHASSIS INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC VALVE For use with remote or wall switch only 1 2 3 NEUTRAL HOT 5 4 3 2 1 5 4 3 2 1 TRANS REM A...

Page 6: ... WIRE TO BROWN WHEN APPLICABLE ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I S TRANSFORMER 3 VAC PLUG IN HOT NEUTRAL FAN REM AUX 5 4 3 2 1 5 4 3 2 1 TRANS THERMOSTAT WIRE ASSEMBLY D Wiring Intermittent Pilot Ignition IPI with 3 Wire Assembly INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC REMOTE RECEIVER TRANSFORMER 3 VAC PLUG IN WH...

Page 7: ...NSMITTER Important Before operating remote control transmitter and receiver must have matching security codes See section Matching Security Codes Important Review Thermo Safety Communication Safety Features under Transmitter Safety Features section These signal temperature safety features shut down the fireplace system when a potentially unsafe condition ex ists Important Review Auto Shutdown sect...

Page 8: ...burner valve operational 6 CLOCK Indicates the current time in AM PM 7 ROOM Indicates CURRENT room temperature 8 O F Indicates degrees Fahrenheit ºC indicates degrees Celsius Transmitter Settings Flip open the plastic cover on the front of the transmitter to expose the SET buttons NOTE Flashing numbers on the display indicate the sys tem is waiting for input such as using the UP and DOWN buttons t...

Page 9: ... gas appli ance the sensing unit in the transmitter will only activate the remote receiver when the temperature change exceeds 20 F 1 ºC above or below the SET desired temperature When the transmitter is in the THERMO mode it should be kept away from direct sources of heat such as fireplaces incandescent lighting and direct sunlight Leaving the trans mitter in direct sunlight for example will caus...

Page 10: ...a transmitter signal is again received The intermittent 4 second beeping will go on indefinitely until reset To reset the RECEIVER and operate the fireplace system 1 Press the MODE button on the transmitter The word ON must display on the LCD screen The THERMO SAFETY and COMMUNICATION SAFETY operation is overridden and the system will return to normal operation depending on the MODE selected at th...

Page 11: ... the room temperature and the system will extinguish Thereafter it should continue to cycle on and off thermo statically approximately every two minutes as the ROOM temperature changes but only when the temperature differential between ROOM and SET temperatures differ at least 2 ºF 1 ºC The 2 ºF differential is the factory setting Timer Operation The countdown timer will operate in either the manu...

Page 12: ...C No s 6732A RF5AN Service Parts No service parts available Troubleshooting To check the operation of the remote 1 Make sure receiver batteries are installed properly If one battery is installed backward receiver will not operate in remote mode Be sure battery output is 5 3 volts or more Slide switch is independent of battery condition 2 Be sure the transmitter s batteries are properly installed a...

Reviews: