Limited Warranty

This REMOTE CONTROL SYSTEM is warranted for 12 
months from the date of purchase or installation to the 
original purchaser to be free from defects in materials 
and workmanship. Damage to the SYSTEM caused by 
accident, misuse, abuse, or installation error whether 
performed by a contractor, service company, or owner, is 
not covered by this warranty. Seller will not be responsible 
for labor charges and/or damage incurred in installation, 

repair, replacement or for incidental or consequential dam-
ages. Batteries and any damage caused by them are not 
covered by this warranty.

Some states, provinces, and nations do not allow exclu-
sion or limitations of incidental or consequential damages, 
so the above limitations or exclusions may not apply. This 
warranty gives you specifi c legal rights. You may have other 
rights that vary by state, province or nation.

•  Cause the RF signal to get lost and not communicate 

with the receiver.

•  Cause the working distance to be shorter than normal.

Specifi cations

Batteries:   Transmitter - 3V 2 ea.;  AAA 1.5V, Alkaline
    

     Receiver:  (4) AA  I-SV  Alkaline

Operating Frequency:  433.92 MHZ

FCC ID No.’s: ULERF-5AN

IC No.’s: 6732A-RF5AN

Service Parts 

No service parts available. 

Troubleshooting

To check the operation of the remote:

1.  Make sure receiver batteries are installed properly. 

If one battery is installed backward, receiver will not 
operate in remote mode. Be sure battery output is 5.3 
volts or more. (Slide switch is independent of battery 
condition).

2.  Be sure the transmitter’s batteries are properly installed 

and that the battery output is 2.7V or more.

3.  Check to make sure the transmitter is communicating 

with the receiver.

•  If the receiver beeps when the MODE button is 

depressed on the transmitter they are communicat-
ing.

•   If the receiver does not beep when the MODE but-

ton is depressed on the transmitter go to Matching 
Security Codes.

4.  Make sure the transmitter is within the 20 feet range of 

the receiver.

5.  Positioning of the receiver is important. If the receiver 

is “enclosed” in a metal surround, the operation of the 
receiver may be affected as noted below. Reposition the 
receiver to improve operating range. It is suggested that 
a heat shield be installed to protect the receiver from 
extreme heat. If the receiver is “enclosed” in a metal 
surround, this can:

Please contact your Hearth & Home Technologies 

dealer with any questions or concerns. 

For the location of your nearest 

Hearth & Home Technologies dealer, 

please visit www.fi reside.com.

Hearth & Home Technologies Inc. 

7571 215th Street West, Lakeville, MN 55044

www.fi reside.com

Summary of Contents for SMART-BATT-II

Page 1: ...two condi tions 1 this device may not cause interference and 2 this device must accept any interference including interfer ence that may cause undesired operation of the device SMART BATT II Remote Control Kits Installation and Operating Instructions INTRODUCTION The remote control system can be operated thermostati cally or manually from the transmitter The system operates on radio frequencies RF...

Page 2: ...URITY CODES and recheck battery position in the remote receiver RECEIVER WIRING INSTRUCTIONS Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appliance and may also damage the remote receiver Make sure the remote receiver switch is in the OFF position Use 18 gauge stranded wires for connections between the terminal wiring block on the millivolt...

Page 3: ...eceiver box see Figure 4 3 WIRE ASSEMBLY PIEZO RED WHITE PILOT THERMOCOUPLE VALVE If your fireplace is wired like Figure 5 remove 3 wires from the valve by unplugging the spade from the valve Install the jumper wire on the terminal on the valve as shown in Figure 6 Then install one of the leads from the receiver onto the valve and the other wire onto the lead from the jumper wire B Wiring Millivol...

Page 4: ... with Rocker Switch REMOTE RECEIVER LEARN ON OFF REMOTE SWITCH PIEZO RED WHITE VALVE PILOT THERMOCOUPLE WIRE TERMINALS IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR ORG WHT VALVE PIGGYBACK ON OFF SWITCH WHITE WIRE CAN BE PLUGGED INTO ANY OF 1 5 LOCATIONS ON THE NEUTRAL SIDE BLACK WIRE CAN BE PLUGGED INTO ANY OF 1 5 LOCATIONS ON THE HOT SIDE BRN BRN PLUG IN GROUND TO FI...

Page 5: ... or wall switch only Take the leads and plug them into wire leads on remote receiver box see Figure 8 ON OFF SLIDE SWITCH BLACK RED BATTERY PACK PIGGYBACK ON OFF SWITCH GRN ORG BROWN BROWN ORANGE WHITE TRANSFORMER 3 VAC PLUG IN GROUND TO FIREPLACE CHASSIS INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC VALVE For use with remote or wall switch only 1 2 3 NEUTRAL HOT 5 4 3 2 1 5 4 3 2 1 TRANS REM A...

Page 6: ... WIRE TO BROWN WHEN APPLICABLE ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I S TRANSFORMER 3 VAC PLUG IN HOT NEUTRAL FAN REM AUX 5 4 3 2 1 5 4 3 2 1 TRANS THERMOSTAT WIRE ASSEMBLY D Wiring Intermittent Pilot Ignition IPI with 3 Wire Assembly INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC REMOTE RECEIVER TRANSFORMER 3 VAC PLUG IN WH...

Page 7: ...NSMITTER Important Before operating remote control transmitter and receiver must have matching security codes See section Matching Security Codes Important Review Thermo Safety Communication Safety Features under Transmitter Safety Features section These signal temperature safety features shut down the fireplace system when a potentially unsafe condition ex ists Important Review Auto Shutdown sect...

Page 8: ...burner valve operational 6 CLOCK Indicates the current time in AM PM 7 ROOM Indicates CURRENT room temperature 8 O F Indicates degrees Fahrenheit ºC indicates degrees Celsius Transmitter Settings Flip open the plastic cover on the front of the transmitter to expose the SET buttons NOTE Flashing numbers on the display indicate the sys tem is waiting for input such as using the UP and DOWN buttons t...

Page 9: ... gas appli ance the sensing unit in the transmitter will only activate the remote receiver when the temperature change exceeds 20 F 1 ºC above or below the SET desired temperature When the transmitter is in the THERMO mode it should be kept away from direct sources of heat such as fireplaces incandescent lighting and direct sunlight Leaving the trans mitter in direct sunlight for example will caus...

Page 10: ...a transmitter signal is again received The intermittent 4 second beeping will go on indefinitely until reset To reset the RECEIVER and operate the fireplace system 1 Press the MODE button on the transmitter The word ON must display on the LCD screen The THERMO SAFETY and COMMUNICATION SAFETY operation is overridden and the system will return to normal operation depending on the MODE selected at th...

Page 11: ... the room temperature and the system will extinguish Thereafter it should continue to cycle on and off thermo statically approximately every two minutes as the ROOM temperature changes but only when the temperature differential between ROOM and SET temperatures differ at least 2 ºF 1 ºC The 2 ºF differential is the factory setting Timer Operation The countdown timer will operate in either the manu...

Page 12: ...C No s 6732A RF5AN Service Parts No service parts available Troubleshooting To check the operation of the remote 1 Make sure receiver batteries are installed properly If one battery is installed backward receiver will not operate in remote mode Be sure battery output is 5 3 volts or more Slide switch is independent of battery condition 2 Be sure the transmitter s batteries are properly installed a...