4

The remote receiver has a 3-position slide switch: OFF/
REMOTE/ON (see Figure 6).

Figure 6.  Remote Receiver

TRANSMITTER

Important: Before operating remote control, transmit-
ter and receiver must have matching security codes. 
See section ‘Matching Security Codes’.

Important:

 Review ‘Thermo-Updating/Communication-

Safety Features’ under ‘Transmitter Safety Features’ 
section. Communication Safety features shut down the 
fi replace system when a potentially unsafe condition 
exists. 

Important: 

Review ‘Auto Shutdown’ section. This safety 

feature shuts down the fi replace after 9 hours of continu-
ous operation, in ON mode only.

Important:

 New or fully charged batteries are essential 

for proper operation of the multi-function transmitter. The 
transmitter operates on 2 AAA-size 1.5V batteries. Use 
Alkaline batteries for longer battery life and maximum 
operational performance.

Insert 2 AAA-size 1.5V batteries into the battery compart-
ment on the back of the transmitter. When the batteries 
are correctly inserted, the screen will display numbers 
(see Figure 7 for LCD Display Screen).

NOTE:

 If the transmitter is activated from a very cold 

condition it may be necessary to allow the transmitter to 
stabilize to room temperature (could take up to 15 min-
utes) before accurate room temperatures are displayed 
on the screen. 

NOTE: 

LCD screen is equipped with a “backlite” for 

easier viewing of LCD screen. Backlite illuminates when 
a function button is depressed. After 5 seconds elapses, 
LCD screen will return to its normal state.

NOTE: The remote receiver will only respond to the 
transmitter when the 3-position slide button on the 
remote receiver is in the Remote position. If the 
system does not respond to the transmitter on initial 
use, see section Matching Security Codes.

1.  With the slide switch in the ON position, the system 

is on.

2. With the slide switch in the REMOTE position, the 

system only operates if the remote receiver receives 
commands from the transmitter.

3. With the slide switch in the OFF position, the system 

is off.

NOTE:

 The slide switch should be placed in the OFF po-

sition if you will be away from your home for an extended 
period of time. Placing the switch in the OFF position also 
functions as a safety “lock out” by turning the system off 
and rendering the remote receiver inoperative.

REMOTE

RECEIVER

Line cord
from fan

LEARN

110/120 VAC, 3A

(Receptacle on back)

Summary of Contents for RCT-MLT-II

Page 1: ...e done by a qualified service technician NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desi...

Page 2: ...the valve Adding Optional Fan Blower Plug 2 prong fan cord directly into the 3 prong polarized plug on the back of the receiver see Figure 3 This receptacle output is 110 120 VAC 3 AMP Wire Colors Ga...

Page 3: ...damage may occur Wiring the Flame Controller 1 Connect the two leads from the flame control solenoid to the orange leads from the receiver 2 Install a manometer into the pressure tap 3 Plug the remot...

Page 4: ...nsmitter is activated from a very cold condition it may be necessary to allow the transmitter to stabilize to room temperature could take up to 15 min utes before accurate room temperatures are displa...

Page 5: ...CURRENT room temperature 8 F Indicates degrees Fahrenheit C indicates degrees Celsius 9 FAN Indicates fan is on or programmed to come on Three speed settings are available Transmitter Settings Flip o...

Page 6: ...e kept away from direct sources of heat such as fire places incandescent lighting and direct sunlight Leaving the transmitter in direct sunlight for example will cause it to read the room temperature...

Page 7: ...RATING MODES the transmitter sends a signal every fifteen 15 minutes to the receiver indicat ing that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a...

Page 8: ...n error whether performed by a contractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damage incurred in installation Timer Operati...

Page 9: ...iring Diagram TRANSFORMER 3 VAC PLUG IN RED BATTERY PACK THERMOSTAT WIRE ASSEMBLY JUMPER WIRE TO BROWN ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PI...

Page 10: ...THERMOSTAT OR REMOTE IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR IGNITION MODULE 3V ON OFF WALL SWITCH LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKE...