Figure 9.  Intermittent Pilot Ignition (IPI) Wiring Diagram

Figure 10.  Standing Pilot Ignition Wiring Diagram

TRANSFORMER

3 VAC

PLUG IN

RE

D

BATTERY PACK

THERMOSTAT

WIRE ASSEMBLY

JUMPER WIRE

(TO BROWN)

OR

A

N

G

E

GR

EE

N

VALVE

GROUND TO

FIREPLACE

CHASSIS

WHITE

ORANGE

IGNITION MODULE 3 VAC

INTERMITTENT PILOT IGNITOR

HO

T

N

E

UT
RA

L

I

S

THERMOSTAT

WIRE ASSEMBLY

PIEZO

WH

IT

E

RED

VALVE

PILOT

THERMOCOUPLE

Summary of Contents for RCT-MLT-II

Page 1: ...e done by a qualified service technician NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desi...

Page 2: ...the valve Adding Optional Fan Blower Plug 2 prong fan cord directly into the 3 prong polarized plug on the back of the receiver see Figure 3 This receptacle output is 110 120 VAC 3 AMP Wire Colors Ga...

Page 3: ...damage may occur Wiring the Flame Controller 1 Connect the two leads from the flame control solenoid to the orange leads from the receiver 2 Install a manometer into the pressure tap 3 Plug the remot...

Page 4: ...nsmitter is activated from a very cold condition it may be necessary to allow the transmitter to stabilize to room temperature could take up to 15 min utes before accurate room temperatures are displa...

Page 5: ...CURRENT room temperature 8 F Indicates degrees Fahrenheit C indicates degrees Celsius 9 FAN Indicates fan is on or programmed to come on Three speed settings are available Transmitter Settings Flip o...

Page 6: ...e kept away from direct sources of heat such as fire places incandescent lighting and direct sunlight Leaving the transmitter in direct sunlight for example will cause it to read the room temperature...

Page 7: ...RATING MODES the transmitter sends a signal every fifteen 15 minutes to the receiver indicat ing that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a...

Page 8: ...n error whether performed by a contractor service company or owner is not covered by this warranty Seller will not be responsible for labor charges and or damage incurred in installation Timer Operati...

Page 9: ...iring Diagram TRANSFORMER 3 VAC PLUG IN RED BATTERY PACK THERMOSTAT WIRE ASSEMBLY JUMPER WIRE TO BROWN ORANGE GREEN VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PI...

Page 10: ...THERMOSTAT OR REMOTE IGNITION MODULE 3 VAC TRANSFORMER 3 VAC GRN ORG INTERMITTENT PILOT IGNITOR IGNITION MODULE 3V ON OFF WALL SWITCH LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKE...

Page 11: ...nition IPI Wiring Diagram Remote Control Wiring Diagrams VALVE GREEN ORANGE JUMPER WIRE TO BROWN PLUG IN TRANSFORMER 3 VAC BLACK RED GROUND TO FIREPLACE CHASSIS WHITE ORANGE INTERMITTENT PILOT IGNITOR...

Reviews: