CB1200 FREESTANDING

Symptom

Possible Cause

Corrective Action

Slow or smoky start-up 

(Cont’d)

Dirty exhaust and/or venting system.

Check for ash build up in appliance, 

including behind rear panels, firebox, heat 

exchanger, exhaust blower and venting.

Feed system fails to 

start. 

Out of fuel.

#2 snap disc may be defective.

Vacuum switch not closing.  No vacuum.

Feed system jammed or blocked.

Feed spring not turning with feed motor.

Feed motor defective or not plugged in.

Check hopper, fill with fuel.

Replace snap disc.  Firebox door must be 

closed securely.

Check exhaust blower is plugged in and 

operating.

Check vacuum switch is plugged in.  

Check vacuum hose is in good condition, 

clear and connected at both ends.

Check thermocouple is in good condition 

and plugged in properly.

Make sure venting system is clean.

NOTE:  High winds blowing into the 

venting system can pressurize the firebox 

causing loss of vacuum.

Empty hopper of fuel.  Use a wet/dry 

vacuum cleaner to remove remaining fuel, 

from hopper, including feed tube.

Check feed chute for obstructions.

Loosen 2 screws and jiggle feed assembly.

Check that set screw is tight on feed 

spring shaft at end of feed motor.

Check connections on feed motor, replace 

if defective.

No call light.  Appliance 

does not begin start 

sequence.

Thermostat not set to a high enough 

temperature.

Snap Disc #3 tripped.

No power.

Fuse blown.

Connections at thermostat and/or appliance not 

making proper contact.

Defective thermostat or thermostat wiring.

Control box defective.

Adjust thermostat above room 

temperature.

Reset snap disc.

Connect to power.

Replace fuse.

Check connections at thermostat and 

appliance.

Replace thermostat or wiring.

NOTE:  To test thermostat and wiring, use 

a jumper wire at the thermostat block on 

the appliance to by-pass thermostat and 

wiring.

Replace control box.

Appliance fails to shut 

off.

Call light on.

Turn thermostat off.

If call light does not go out, disconnect 

thermostat wires from appliance.  If call 

light does go out, thermostat or wires are 

defective.

Summary of Contents for Quadra-Fire CB1200M-MBK

Page 1: ...tallation inspection and permits Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies recommends HHT Factory Trained or NFI certified professi...

Page 2: ...t appareil une chemin e servant un autre appareil Utilisez syst m de ventilation L ou P diam tre 76mm ou 102mm C C D B E E A B C C Listed Solid Fuel Room Heater Pellet Type Insert Also suitable for Mo...

Page 3: ...and Fuel Storage 9 E Before Your First Fire 10 F Filling the Hopper 10 G General Operating Information 10 H Starting Your First Fire 10 I Fire Characteristics 11 J Feed Rate Adjustment Instructions 11...

Page 4: ...ectronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free cerami...

Page 5: ...rranging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warrant...

Page 6: ...e to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS...

Page 7: ...data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and high EPA tests Based on the maximum feed rate per hour multiplied by...

Page 8: ...o the State of California to cause birth defects or other reproductive harm For more information go to WWW P65Warnings ca gov NOTE Hearth Home Technologies manufacturer of this appliance reserves the...

Page 9: ...ned more frequently The only change in operation is that the feed rate may require a slight adjustment The BTU output of the appliance varies slightly compared to pellets depending on the quality of t...

Page 10: ...e empty and the fire pot floor is fully closed 3 Check the position of the thermocouple located above the fire pot and make sure that it protrudes approximately 3 4 inch 19mm into the fire pot 4 Close...

Page 11: ...approximately 4 to 6 inches 102 to 152mm If the fire has tall flames with black tails and seems somewhat lazy the feed rate will need to be reduced This is done by sliding the fuel adjustment control...

Page 12: ...and should always remain in RUN unless items are being adjusted NOTE When thermostat is set to Manual non programmable mode all positions of the SET slide switch will act like RUN UP DOWN BUTTONS The...

Page 13: ...between state changes NOTE This delay does not happen when the thermostat is manually turned up and down ITEM 08 TEMPERATURE DIFFERENTIAL The thermostat works by turning your heating system on and off...

Page 14: ...UP or DOWN buttons to adjust the start time and set temperature for the MORN event and then press NEXT button to advance 4 Adjust the start time and set temperature of the DAY event then press NEXT b...

Page 15: ...a hardware reset is performed however the clock will have to be changed to match the current day and time Figure 15 1 Figure 15 2 Figure 15 5 S Thermostat Battery Replacement This thermostat is power...

Page 16: ...the operation or longevity of your insert 2 Ash buildup on glass 2 This is normal Clean the glass 3 Glass has turned dirty 3 Excessive build up of ash The lower burn settings will produce more ash the...

Page 17: ...n Daily X Ash Removal from Firebox More frequently depending on the fuel type or ash build up OR X Beneath Heat Exchanger Every 1 ton of fuel OR X Blower Combustion Exhaust More frequently depending o...

Page 18: ...he same ash pan as the fire pot debris The ash pan should be emptied every time you clean the firebox Remember to place the ash and debris into a metal or noncombustible container e The 2 cleaning sli...

Page 19: ...pending on ash build up By Homeowner a Be sure the appliance is allowed to cool has been unplugged and the exhaust blower is off b Remove access door on the right of the appliance 4 screws c Use a sma...

Page 20: ...are heavy duty vacuum cleaners specifically designed for solid fuel appliance cleaning Handle glass with care Inspect the gasket to ensure it is undamaged Do NOT strike slam or scratch glass Do NOT o...

Page 21: ...s that may be in the drop tube Exposed Heat Exchanger Tubes Drop Tube Figure 21 1 Clean Out Plate Removed Exhaust Blower Clean Out Plate Remove 4 Screws Open Right Side Panels Figure 21 2 Figure 21 3...

Page 22: ...even though monthly cleaning may be enough in the coldest months Contact your local municipal or provincial fire authority for information on how to handle a chimney fire In the event of a soot or cr...

Page 23: ...ontrol box Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot clean out plate is fully closed Clean fire...

Page 24: ...loss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly Ch...

Page 25: ...ck panels Change fuel brand to premium Check that fire pot clean out plate is fully closed Reduce feed rate using feed rate adjustment control rod located inside hopper Nuisance shutdowns Low flame Sa...

Page 26: ...TE When removing the side glass with the door latch you must remove the door latch first before removing the side frame Use a powered Phillips head screw driver to remove the 4 screws a Be sure the ap...

Page 27: ...shut down the appliance and let it completely cool down and then unplug it and remove the ash drawer 2 Follow instructions to remove the ash pan found on page 14 Remove the access plate directly abov...

Page 28: ...edures to shut down the appliance and let it completely cool and then unplug it b Use an 11 32 wrench or nut driver to loosen and remove the 6 nuts holding motor mount plate to the blower housing on y...

Page 29: ...the blue light will automatically start blinking 1 blink every 10 seconds for the first 60 seconds and then will stop E NOTE Do NOT open the control box This will void the warranty If you need to plu...

Page 30: ...opper If the fire tries to burn back into the feed system or push exhaust up the feed tube this snap disc will shut the entire system off This disc must be manually reset 20 Vacuum Switch The vacuum s...

Page 31: ...erminal Block Center 2 screws for Thermostat Wires Cleaning Rods Heat Exchanger Tubes Figure 31 1 Figure 31 2 Figure 31 3 Heat Output Fan Speed Reset Button Call Light HIGH HIGH MED LOW LOW Outside Ai...

Page 32: ...32 January 28 2019 7014 259E CB1200 FREESTANDING C Service and Maintenance Log Date of Service Performed By Description of Service...

Page 33: ...33 January 28 2019 7014 259E CB1200 FREESTANDING D Exploded Drawings...

Page 34: ...34 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 35: ...35 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 36: ...36 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 37: ...37 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 38: ...38 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 39: ...39 January 28 2019 7014 259E CB1200 FREESTANDING...

Page 40: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Reviews: