![Hearth and Home Technologies PVK-80 Installation Instructions Manual Download Page 11](http://html.mh-extra.com/html/hearth-and-home-technologies/pvk-80/pvk-80_installation-instructions-manual_2114483011.webp)
11
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
(ORANGE)
(GREEN)
GROUND
BLACK
IPI
VALVE
FLAME
SOLENOID
(BLACK)
(WHITE)
(GROUND)
TO HEAT ZONE
FAN
CONNECTION
(BLACK)
(BLACK)
AC
PLUG
FLAME HIGH/LOW
FLAME ON
(RED)
(RED)
(ORANGE)
(ORANGE)
GROUND PIGTAIL
GREEN
JUNCTION BOX
(YELLOW)
(YELLOW)
FACTORY
CONNECTED
TOGETHER
FAN THEMOSTAT
AUX
CONNECTION
(BLACK)
PLUG-ADP
IPI
MODULE
IPI PILOT
3V DC
(BLACK)
(RED)
(BROWN)
(BROWN)
RED
GREEN
YELLOW (H&G)
WHITE (HTL)
REAR VIEW
FRONT VIEW
FIREBOX
BACK
LIGHT 1
BACK
LIGHT 2
R
Y
G
G
Y R
PVK-80 POWERVENT
(BLACK)
(BROWN)
(RED)
(WHITE)
(WHITE)
(BLACK)
(BROWN)
(RED)
(BROWN)
(BROWN)
(RED)
(BLACK)
(GREEN)
NOTE 1: BROWN AND RED WIRES FROM
PVK-80 ARE FOR THE VACUUM SWITCH
NOTE 2: BLACK, WHITE AND GREEN WIRES
RUN PVK-80 MOTOR.
NOTE 3: GREEN WIRE FROM PVK-80 SHOULD
TIE INTO GROUND A THE JUNCTION BOX
WHERE 110V SERVICE IS REQUIRED.
Figure 19. IPI Wiring Diagram For WSK-MLT