background image

#455-0770B  February 9, 2006  Page 2 of 3

Figure 5

   Remove the pilot assembly by disconnecting all 

the leads from the valve leading to the pilot.  The leads 

may be cut as a new pilot assembly is supplied in the kit.

Figure 6

   Disconnect thermocouple, thermopile and pilot 

line from the valve.

Figure 7

   Remove the pilot bracket and pilot from the appli-

ance  and  discard  the  screws.    Install  the  new  pilot  and 

pilot bracket using screws from the kit. 

Figure 8

   Seal around the pilot and thermocouple, ensuring 

the  sealant  penetrates  through  the  bottom  of  the  appli-

ance.

Figure 9

   Bend hand-bends to form bulkhead retainer to 

shape, and install in the appliance. (This will replace the 

old right hand burner bracket.)

Figure  10

      Bulkhead  retainer  attaches  to  the  appliance 

bottom as well as to the pilot bracket, as indicated. 

    NOTE:  An NG pilot is provided. An LP orifice is    

 

    included for conversion, if necessary.