Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev F • 1/2011
7
Fire Risk
Explosion Risk
Personal Injury Risk
Failure to position the parts in accordance
with the diagrams provided with the log
packages or failure to use only parts
approved with this appliance may result in
J. Damper Stop Installation Instructions
Included in the burner assembly box is a damper stop clamp
which attaches to the damper as shown (Figure 6). Install
the clamp to the damper ensuring that the minimum require-
ments (Tables 1 and 2) are achieved. Use a 7/16 in. wrench
to secure the clamp to the damper. If the damper clamp pro-
vided does not fit your application, other means of securing
the proper opening must be provided by the installer.
Figure 6
Damper Stop Clamp
Note:
The state of Massachusetts requires that the
chimney flue damper, when used with gas logs, be welded
open or completely removed. In the Commonwealth of
Massachusetts this appliance must be installed by a
licensed plumber or gasfitter.
K. Inspect the Venting System
The fireplace venting system is designed and constructed to
develop a positive flow adequate to remove flue gases to the
outside atmosphere. See fireplace installation instructions.
A spillage test must be made before the installed
appliance is left with the consumer.
• Close all doors and windows in the home.
• Light the log set (see Lighting Instructions).
• After three minutes, test with a smoke match, smoke
candle, stick incense or cigarette 1 in. below the top of
the opening (lintel) moving across the full width. If spillage
(smoke down into the room) occurs, it will most likely be
near the top, outside corners.
Possible cures if spilling occurs:
• The damper needs to be opened further.
• The fireplace opening needs to be reduced by adding a
drop panel across the top under the lintel.
• The air supply from outdoors needs to be increased. Open
the outside air kit if the appliance is so equipped, or crack
open a door or window.
• If necessary, seek expert advice. Do not operate this
appliance.
Cleaning
• Periodic examination and cleaning of the venting system
of the fireplace should be done before initial use and at
least annually by a qualified agency.