5
Specifications
Table 5.
Specifications
Specifications
Single−Core HRV Units
Dual − Core
HRV Unit
Single−Core ERV Units
Model No.
HRV3−150−TPD
(17Y64)
HRV5−150
(17Y58)
HRV5-200-TPD
(17Y62)
HRV6-HEX095-
TPD (17Y52)
HRV5-270-TPD-
ECM
(17Y53)
HRV3−195
(Y2143)
ERV5-130
(17Y54)
ERV5-150-TPD
(17Y55)
ERV5-175-TPD
(17Y57)
Energy Star®
certified
(Canada Only)
No
No
No
These products earned the ENERGY STAR
®
by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. These
products meets ENERGY STAR
®
requirements only when used in Canada.
Unit Weight
in pounds
(kilograms)
45 (20)
62 (28)
58 (26)
59 (27)
59 (27)
82 (37)
41 (19)
42 (19)
54 (24)
Unit
Dimensions
Refer to dimension drawings starting with “Figure 1. Dimensions and Airflows” on page 7.
*High Speed (HVI Certified)
inches w.g. (Pa)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
CFM (L/s)
0.1 (25)
170 (80)
170 (80)
203 (96)
110 (52)
280 (132)
222 (105)
133 (63)
161 (76)
195 (92)
0.2 (50)
155 (73)
159 (75)
193 (91)
104 (49)
273 (129)
210 (99)
129 (61)
155 (73)
184 (87)
0.3 (75)
148 (70)
148 (70)
182 (86)
97 (46)
267 (126)
195 (92)
125 (59)
146 (69)
172 (81)
0.4 (100)
136 (64)
140 (66)
172 (81)
89 (42)
261 (123)
176 (83)
123 (58)
138 (65)
161 (76)
0.5 (125)
125 (59)
125 (59)
159 (75)
81 (38)
254 (120)
157 (74)
119 (56)
127 (60)
150 (71)
0.6 (150)
114 (54)
148 (70)
72 (34)
248 (117)
133 (63)
112 (53)
117 (55)
140 (66)
0.7 (175)
102 (48)
136 (64)
61 (29)
242 (114)
108 (51)
108 (51)
104 (49)
129 (61)
0.8 (200)
89 (42)
121 (57)
49 (23)
235 (111)
83 (39)
102 (48)
93 (44)
117 (55)
0.9 (225)
76 (36)
108 (51)
227 (107)
57 (27)
95 (45)
83 (39)
106 (50)
1.0 (250)
57 (27)
93 (44)
220 (104)
87 (41)
74 (35)
93 (44)
*Adjusted
Sensible
Recovery
Efficiency
@ 32 °F (0ºC)
@ 66 CFM
(31 L/s) 68%
@ 64 CFM
(30 L/s) 82%
@ 64 CFM
(30 L/s) 82%
@ 64 CFM
(30 L/s) 79%
@ 64 CFM
(30 L/s) 77%
@ 64 CFM
(30 L/s) 87%
@ 64 CFM
(30 L/s) 77%
@ 64 CFM
(30 L/s) 82%
@ 66 CFM
(31 L/s) 85%
*Sensible
Recovery
Efficiency
@ 32 °F (0ºC)
@ 66 CFM
(31 L/s) 61%
@ 64 CFM
(30 L/s) 75%
@ 64 CFM
(30 L/s) 76%
@ 64 CFM
(30 L/s) 75%
@ 64 CFM
(30 L/s) 75%
@ 64 CFM
(30 L/s) 81%
@ 64 CFM
(30 L/s) 72%
@ 64 CFM
(30 L/s) 75%
@ 66 CFM
(31 L/s) 75%
*Adjusted
Sensible
Recovery
Efficiency
@ -13 °F
(−25ºC)
@ 76 CFM
(36 L/s) 65%
@ 69 CFM
(33 L/s) 76%
@ 102 CFM (48
L/s) 73%
@ 68 CFM
(31 L/s) 68%
@ 70 CFM
(33 L/s) 71%
@ 114 CFM
(54 L/s) 70%
N/A
@ 70 CFM
(33 L/s) 64%
@ 68 CFM
(32 L/s) 62%
*Sensible
Recovery
Efficiency
@ -13 °F
(−25ºC)
@ 76 CFM
(36 L/s) 61%
@ 69 CFM
(33 L/s) 72%
@ 102 CFM (48
L/s) 70%
@ 68 CFM
(31 L/s) 65%
@ 70 CFM
(33 L/s) 70%
@ 114 CFM
(54 L/s) 68%
@ 53 CFM
(25 L/s) 54%
@ 70 CFM
(33 L/s) 60%
@ 68 CFM
(32 L/s) 58%
*Latent
Efficiency
95ºF (35ºC)
N/A
N/A
N/A
N/A
N/A
N/A
@ 64 CFM
(30 L/s) 38%
@ 66 CFM
(31 L/s) 43%
@ 64 CFM
(30 L/s) 41%
*Total
Efficiency
95ºF (35ºC)
N/A
N/A
N/A
N/A
N/A
N/A
@ 64 CFM
(30 L/s) 44%
@ 66 CFM
(31 L/s) 48%
@ 64 CFM
(30 L/s) 48%
* Certified by the Home Ventilating Institute (HVI) according to test procedures developed by HVI members and based on internationally recognized standards. For
performance ratings at other conditions not shown, please visit the HVI website.
Number
of speeds
available with
S30/E30 and
basic wall
control
2
2
2
2
2
2
2
2
2
Summary of Contents for ERV5-130