Health Craft SP-HD Installation Instructions Manual Download Page 8

Figure 9.

21

2

20

Figure 10.

Figure 11.

Figure 12.

HealthCraft Products Inc., Ottawa, Ontario, Canada. Copyright 2006. Specifications subject to change without notice.

Page 6 of 8

 

SUPERPOLE™ PREPARATION
C1. 

See step A1 on page 2. Complete these instructions and then 

continue with step

 C2.

SUPERTRAPEZE™ PREPARATION
C2.

 Unpack the support arm (20) from the rectangular box. Slide 

support arm (20) onto the top end of the pole (2) such that the strap 
hook is down as shown in 

Figure 9

.  Move it gently down the pole until 

it rests against the top of the grey grip (21).  

C3.

 Determine Location of Pole (bedside use) - Refer to  

Figure 10

The actual user of the SuperTrapeze™ should lie down in bed in their 
normal resting position.  The location of the pole alongside the bed is 
recommended to be directly beside the hip/belt line as shown.  Also, 
it is recommended to situate the pole as close to the side of the bed 
as possible while leaving enough clearance for the bed coverings.

SUPERPOLE™ INSTALLATION
C4.

 See steps 

A2

 through 

A7

 on page 2. These steps will guide you 

to raise and secure the pole in the location as determined in steps 

C3

Complete these instructions and then continue with step 

C5

.

SUPERTRAPEZE™ INSTALLATION
C5.

 Once the pole has been installed beside the bed, hold the trapeze 

handle under the support arm, such that  the upper rail of the handle 
is closest to the head of the bed as shown in 

Figure 10

.  Next, open 

the loop on the end of the trapeze strap (22), rotate the strap 180 
degrees, and slide it on to the upper rail of the trapeze handle (23) as 
shown in 

Figure 11

.  Slide it past the grip and along the trapeze tube 

until it reaches the top bend of the trapeze as shown in 

Figure 11

.  

SETTING HEIGHT OF SUPPORT ARM
C6.

 Using a tape measure, make a small pencil mark on the pole at a 

suggested height of 84" from the floor  as shown in 

Figure 10

.  Have 

the actual user lie down in bed in their normal lying position with their 
hands placed palm down on their thighs. Locate the cone point set 
screws (25) and allen wrench (24) and have them close at hand.  
Gently slide the support arm up the pole until the top of the barrel 
reaches the 84" mark as shown by "Y" in 

Figure 10

. Next, swing the 

support arm so that the strap hangs directly over the palms of the user 
as shown by "X". Secure the support arm to the pole with one of the 
set screws (25) and allen wrench (24) as shown in 

Figure 12

.

SETTING HEIGHT OF TRAPEZE HANDLE
C7.

 Set the trapeze at an appropriate height by adjusting the length of 

the strap. This is done by pulling some slack through the cross pieces 
of the strap buckle and pulling the buckle down to shorten the strap, 
or sliding it up to lengthen the strap. The trapeze handle is at an 
appropriate height when ones fingers can comfortably grasp around 
the bottom rail of the trapeze when lying down in bed as shown by "Z" 
in 

Figure 10.

TESTING THE LOCATION
C8.

 Have the user gently try the installed location of the trapeze 

handle and pole. Ensure that the trapeze handle is not too close to 
allow a comfortable sit up action.  Should the trapeze support arm 
need to be moved, remove the set screw installed in step 

C6

, and lift 

the support arm up by at least one inch and reinstall the screw with 
the arm at a new angle to avoid the set screw being too close to the 
previous indent created in the pole by step 

C6

.

SECURE SUPPORT ARM
C9.

 Once the trapeze has been confirmed as the correct location, fully 

install all three set screws. 

 IMPORTANT 

- The set screws should be 

installed such that the back end of the screw is flush with the outer 
surface of the support arm or injury may result.  Slide the spring collar 
(26) down over the top of support arm as shown to retain the screws 
in service.

Your SuperPole™ with SuperTrapeze™ is now installed. 

25

24

22

26

23

Y=84”

X

Z

SUPERTRAPEZE™ INSTRUCTIONS

Prior to installing the SuperPole™ with SuperTrapeze™, 
we recommend that you first read these instructions.

Summary of Contents for SP-HD

Page 1: ... moving from cooking surface to kitchen table Tubular Ring Tray Floor to Ceiling Range Uni Fit Extender SuperPole Ultra Ceiling Plate Extender Pole Material Grip Material Expansion Mechanism Weight Capacity Assistance Level Typically 28 38 71 97cm from floor 18 46cm diameter 1 25 3 175cm diameter tube for easy gripping 14 36cm diameter A B S tray easy to wipe clean Weight capacity 15lbs 7kg 93 99 ...

Page 2: ... recommended that the tubular ring of the Safety Island TM is approximately 28 36 from the floor this height is determined by the height of the user consult your therapist Fasten the Safety Island TM to the pole by installing and tightening the three set screws 28 with the provided hex key wrench 29 You will need to slide the spring ring 30 downwards to gain access to the screw holes IMPORTANT The...

Page 3: ...more than mild support for side to side stability 2 You are not able to inspect or have inspected and tighten if necces sary the exension screw on a monthly basis WARNING PATIENT ENTRAPMENT The potential risk of entrapment limb neck head torso between the pole and adjacent item i e bed can be reduced or avoided by the following strategies 1 Situate the pole at a distance that is considerably small...

Page 4: ... in the room such as wall corners etc HINT It is easier to swing the pole up from one of the sides of the ceiling anchor plate as shown in Figure 3 If the ceiling anchor plate hits the ceiling prior to reaching vertical you will need to shorten the length of the extension screw SUPERPOLE INSTALLATION A5 While the cover sleeve 6 is held up insert a bar such as the shaft of a screwdriver through the...

Page 5: ...01 Grip 20 long SP 114 Plastic Cover Sleeve SP 107E Extension Screw SP 105E Collar SP 172E Jam Nut SP 145 Plastic Washer PARTS DIAGRAM SUPERPOLE HW 323 Hitch Pin HW 302 Clevis Pin HW 318 Nylon Washer SP 117 Top Rubber SP 115P Top Plate SP 115PA Top Plate Heavy Duty SP 115PB Top Plate Ultra GR 101 Grip 20 long SP 113P Pole SP 113PA Pole Heavy Duty SP P Pole Assembly SP 402 Base Plate Assembly SP 40...

Page 6: ...B5 Once the grooved collar 14 has been set to its desired location fasten the grooved collar to the pole 2 by installing and tightening the three set screws 15 with the larger hex key wrench 16 You will need to slide the spring collar 17 upward to gain access to the screw holes IMPORTANT These screws MUST be tightened until the back end of the screw is flush with the collar or injury may result By...

Page 7: ... Spring Ring SP 501 SuperBar Parts Pack PARTS DIAGRAM SUPERPOLE with SUPERBAR GR 101 Grip 20 long SP 402 Base Plate Assembly SP 112P Base Plate SP 118 Base Plate Rubber SP 403 Ceiling Anchor Plate Assembly SP 115 Top Plate SP 117 Top Rubber HW 302 Clevis Pin HW 318 Nylon Washer HW 323 Hitch Pin SP P Pole Assembly SP 113P Pole GR 101 Grip 20 long SP 114 Plastic Cover Sleeve SP 107E Extension Screw ...

Page 8: ... actual user lie down in bed in their normal lying position with their hands placed palm down on their thighs Locate the cone point set screws 25 and allen wrench 24 and have them close at hand Gently slide the support arm up the pole until the top of the barrel reaches the 84 mark as shown by Y in Figure 10 Next swing the support arm so that the strap hangs directly over the palms of the user as ...

Page 9: ...6 24x Cone Point x3 HW 320 Hex Key Wrench 5 32 long arm GR 101 Grip 20 long SP 402 Base Plate Assembly SP 112P Base Plate SP 118 Base Plate Rubber SP 403 Ceiling Anchor Plate Assembly SP 115 Top Plate SP 117 Top Rubber HW 302 Clevis Pin HW 318 Nylon Washer HW 323 Hitch Pin SP P Pole Assembly SP 113P Pole GR 101 Grip 20 long SP 114 Plastic Cover Sleeve SP 107E Extension Screw SP 105E Collar SP 172E...

Page 10: ...r counter Use the tray to place items while moving from cooking surface to kitchen table The Safety Island is a unique circular ring with a tray that mounts at any height to the SuperPole The Uni Fit Extender is added to the SuperPole to increase its height range from 93 99 to 100 120 NOTE Not to be used with the SuperTrapeze The Ceiling Plate Extender is added to the standard SuperPole ceiling pl...

Reviews: