- 3 -
3.4 Reset
There is no need to clear the memory before programming a new calibration
value. You can overwrite the previous setting easily.
However, if you wish to clear all settings and go back to defaults:
Press
BOTH
buttons on the unit and keep it depressed until [
E
] is indicated.
When the unit is powered up with default parameters, [
A 0
] is displayed.
This means memory bank A is active with no calibration. The unit will work in
Transparent mode
, i.e. the speedometer will read the same as with no SH
installed.
3.5 Switching between A and B calibration value
Press
SET
until the active memory bank ([
A
] or [
b
]) is displayed and keep it
depressed for one more second, until the value switches.
When you program a calibration value (chapter 3.2), you can program the value
in the active memory bank only.
3.6 Activating the Km/h to MPH conversion feature
Press
SEL
until the actual mode ([
C
] or [
-
]) is displayed and keep it depressed for
one more sec, until the value switches.
When Km/h to MPH conversion is active, the indicated speed and distance travelled
will be converted, but the displayed units of measure (km/h and km) won't be
changed.
It is possible to switch on/off the Km/h to MPH conversion only.
If you wish to use MPH to Km/h conversion, you have to p60.9% (1.609
multiplier) on top of the calibration value you need. However, keep in mind that
your speedometer’s maximum reading will not be changed. E.g. a speedo with
160 MPH highest reading will not be able to show over 160 Km/h after conversion.
3.7 Test mode
In Test mode, you can check whether the SH is installed and working properly.
To initiate test mode:
- Make sure the ignition is OFF (unit is powered down).
- Press
SEL
and keep it depressed while you turn the ignition ON.
[
t
] (test) is now indicated. Release the button.
The speedo should indicate a number other than zero.
If you wish, you can
change the speed reading in 9 steps by pressing
SET
repeatedly.
- Rotate the wheels. [
t
]
should be blinking as the wheels turn.
- Press
SEL
to exit from Test mode. The unit will work normally.