- 2 -  
 

 

3. Setting and Using your SH 

 

3.1

 

Preparation 

1.

 

Ensure that the unit is installed correctly by executing the SH Test instructions 

(Refer to chapter 3.7)

2.

 

Determine the Calibration value needed for your application. Use the online 

calculator on our website or download the SpeedoHealer calculator app. 

(For calculation formula, refer to chapter 4). 

3.

 

Turn ignition ON. 

 

 

3.2 Programming a calibration value 

 Entering into programming mode does not clear the previous setting, so you 

can update a previously stored calibration value easily. 

 All settings are stored in Flash memory. No need to repeat programming after 

the battery or the SH box has been disconnected. 

 
 

1.

 

Press 

BOTH buttons

 on the unit until [

L

] is indicated. 

 

2.

 

The Sign of the calibration value is blinking: 

[

-

] : Negative 

[

P

] : Positive 

To toggle the Sign, press the 

SET

 button. 

 

 If the Sign you set is Negative, you will program 3 digits (max value: 99.9) 

If Positive sign was selected, you need to enter 5 digits (max value: 9999.9) 

 You need to enter all digits (including the leading zeros), e.g. enter -07.5 if 

you want to program -7.5% 

 

3.

 

Press 

SEL

 to proceed to the first digit of the calibration value. 

[

n

] (next) is shown, and then the value of the first digit will blink. 

Press 

SET

 repeatedly until the desired value is shown. 

Repeat this step until all digits are entered. 

 

4.

 

After the last digit has been entered, press 

SEL

 to exit from programming mode. 

[

o

] (over) is shown, and then the unit will display the programmed digits in 

order, just like any time ignition is turned ON. 

 

 

3.3 Reviewing the calibration value in use 

Whenever the ignition key is turned ON, the unit will show the following 
information in order: 

-  Memory bank in use: either [

A

] or [

b

-  Sign of the Calibration value: [

-

]: Negative, [

P

]: Positive 

-  Calibration value without leading zeros 

-  Conversion mode active [

C

] or not (blank) 

 

Examples: 

[

A 0

] means memory bank A is active with no calibration (factory default) 

[

A - 7. 5

] means memory bank A is active with -7.5% calibration 

[

A – 1 2. 5 C

] bank A is in use with -12.5% and Km/h conversion is enabled 

[

A P 5. 0

] means memory bank A is active with +5.0% calibration 

[

b P 6 2 3 4. 5 C

] bank B, +6234.5% and Km/h conversion is enabled 

Summary of Contents for SPEEDOHEALER v4

Page 1: ... 9999 9 in steps of 0 1 This means the signal can be adjusted from 1 1000 to x100 in increments of 0 001 This range is efficient even for the most radical conversions and suitable for all kinds of custom applications as well e g different engine gauge combination bike engine powered cars etc Dual Bank Memory Allows storing two independent calibration values and switching among them is possible by ...

Page 2: ...999 9 You need to enter all digits including the leading zeros e g enter 07 5 if you want to program 7 5 3 Press SEL to proceed to the first digit of the calibration value n next is shown and then the value of the first digit will blink Press SET repeatedly until the desired value is shown Repeat this step until all digits are entered 4 After the last digit has been entered press SEL to exit from ...

Page 3: ...ressed for one more sec until the value switches When Km h to MPH conversion is active the indicated speed and distance travelled will be converted but the displayed units of measure km h and km won t be changed It is possible to switch on off the Km h to MPH conversion only If you wish to use MPH to Km h conversion you have to program 60 9 1 609 multiplier on top of the calibration value you need...

Page 4: ...e 9 09 9 1 5 Warranty The SpeedoHealer is built to last all leads are protected against reverse voltage short circuits and high energy transients Only high quality components are built in and the epoxy resin encasing provides extreme protection for the internal parts from shocks vibrations and water To ensure trouble free operation all units are extensively tested prior to shipment Should you not ...

Reviews: