Head Rush Technologies requires anchor points to have a minimum load ca-
pacity of 12 kN (2640 lbs) in expected directions of application. Other national
and international standards for anchor points may apply and require higher
load capacity. Consult with the authority having jurisdiction for your required
load capacity.
The location and anchor points for the QuickFlight Free Fall Device should
comply with the following:
Anchor points are not to be used by additional devices or as attach-
ments for hardware not associated with the Free Fall Device installation.
Anchor points should be of a suitable size to correctly install any mount-
ing hardware.
8.2.2 HARNESS
All harnesses used in conjunction with the QuickFlight Free Fall Device must
comply with one or more of the following standards or an equivalent standard
for your jurisdiction:
EN 361 - Personal protective equipment for prevention of falls from a
height – Full body harness.
EN 813 - Personal protective equipment for prevention of falls from a
height – Sit harness.
EN 12277 - Type A. Full Body Harness.
EN 12277 - Type B. Small Full Body Harness.
EN 12277 - Type C Sit Harness.
Harnesses must be of the correct size and fitment and be in serviceable condition.
8.2.3
SECONDARY CONNECTORS
All secondary connectors and hardware used in the installation of the Quick-
Flight must conform to the requirements of:
EN 362 - Types of connectors for personal protection.
EN 12275 - Types of connectors for mountaineering.
All connectors, hooks, D-rings and shackles used to mount the QuickFlight
must be of compatible size, shape and strength for the mounting point to
which they are attached.
IT IS THE OWNER/INSTALLER’S RESPONSIBILITY TO ENSURE COMPAT-
IBILITY OF CONNECTORS IN DEVELOPING THE HARNESS/CONNEC-
TION SAFETY SYSTEM. INCOMPATIBLE CONNECTIONS CAN RESULT IN
SERIOUS INJURY OR DEATH DUE TO UNINTENTIONAL DISCONNEC-
TION DURING FREE FALL/DESCENT.
22