c) Click the button in ‘Mode’ column of channel 1, select ‘Other Security Level’ for mode
type, enable ‘Vacation’, then save.
d) Click the button in ‘Mode’ column of channel 2, select ‘Other Security Level’ for mode
type, enable ‘Vacation’, enable ‘entry delay times’, select ‘2X’(suppose this door is far
away from the HDL-MPL8.48, and it takes more time to disarm when enter from this door,
then can select its entry delay time is two/four times of Entry Delay), then save.
e) When press the arm button, the senor will start to detect the status of these three
channels to check whether they are in normal states or not. If all of them are ‘Close’, then
the security will start to arm after Exit Delay. If one of them is not in the normal state(e..g.
channel 1 shows ‘OFF’ status, the main door is still open), then it will fail to arm until you
close this door.
The users can double click index1/2/3 rows to set some warning targets when fails to arm.
e.g. if chann1 is OFF when trying to arm, will play the 5
th
warming tone from the Z-Audio,
Summary of Contents for Buspro HDL-MSM.431
Page 19: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 16 5 9Arm Flow ...
Page 24: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 21 5 10 3Night Mode ...
Page 25: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 22 5 10 4 Fire Mode ...
Page 26: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 23 5 10 5 Gas leakage ...
Page 27: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 24 5 10 6 Silent panic ...
Page 29: ...User Manual SB DN SEC250K Advanced Security Controller User Manual 26 5 10 8 Panic ...