6 Using the heating system – Heating up the system
55
30.
Open the ash door (1).
31.
Wait until the progress bar is completely full.
✓
The
Close doors
message appears in the display.
32.
Close the ash door (1).
✓
The HDG Euro 30/40/45/50 boiler is now heated up.
E
LECTRICAL
IGNITION
16.
Place some highly flammable material (small pieces of dry wood)
in front of the igniter gun and approx. 15 - 20 cm high on the
burner nozzle on the grate.
17.
Lay some small pieces of cardboard in front of the igniter gun on
the wood inside the fuel chamber.
18.
Fill up the fuel chamber with fuel.
19.
Close the fuel chamber door.
✓
The
Clean, reload, ignite
message appears in the display.
Figure 6/17 - Opening the ash door
1
Figure 6/18 - Closing the doors
Only put in as much wood as the heating system and accumulator
can absorb as energy.
Figure 6/19 - Cleaning, reloading, igniting
1