background image

15

Wi-Fi Setup

ThermoLinx:

 This is 

only

 for HBX Thermostats, snow 

melt, boiler and geothermal controllers. Please 

do not enter any information.

TLBTU:

 This is for 

only

  SensorLinx  Heat  Sensors. 

Please input the last four digits of your ThermoLinx 

network.

Network SSID:

 Enter the Wi-Fi network name that 

the system will connect to. (Case Sensitive)

Password:

 Enter the Wi-Fi network password. 

Network name cannot contain more than 30 

characters. The password should not contain any 

special  characters.  If  using  WEP  64bit  or  128bit 

security must not be in Shared Mode. If using WEP 

128bit, the password/key must be 26 characters 

long

After entering all the required information please 

select  “Device  Setup”.  The  control  will  now 

establish  connecting  ThermoLinx  to  your  Wi-Fi 

network. Please allow for 120 seconds to connect 

to your Wi-Fi Network. 

LED Lights

Once connected check the red, green, 

and blue LED lights on the WFS-0100. All 

LED lights should be steady.

 If you do not see the above description 

on the control you are not connected to 

a Wi-Fi network.

  

Solid Green Only:

 incorrect password

S

olid Red and Green:

 ThermoLinx is connected to your Wi-Fi but your network port 

1314 is closed and not allowing communication to the HBX server, please contact 

your internet provider to rectify this.

Connections can only be made to a 2.4GHz network.

CONNECTING TO A NETWORK (IOS)

100%

9:41 AM

WiFi Setup

--°F

Add Name Here

Connect to WiFi Now

Network SSID

Network Password

CHOOSE A NETWORK

Home Network

ThermoLinx

Home Network

1234

Summary of Contents for SensorLinx BTU-0014

Page 1: ...HBX Control Systems Inc Installation Manual SensorLinx Heat Meter Installation Guide Version 1 00 BTU 0014 BTU 0030 BTU 0070 BTU 0130 BTU 0400...

Page 2: ...as permanent damage to the equipment Proceed with caution Moderate Hazard This action may cause personal injury or have adverse effects on the installation process if handled incorrectly Disconnect Po...

Page 3: ...kept in its original shipping carton prior to installation In order to retain the warranty coverage it should be stored properly Store within an ambient temperature range of 10 C to 40 C If possible...

Page 4: ...stem the system allows for accurate Heat measurement SENSOR REPLACEMENT If one of the sensors fails or must be replaced when being used in Heat Meter configuration both the WFS and WPS sensors must be...

Page 5: ...o 24 Meets UL Standard 873 ETL Control No 3068143 Storage 10 C to 40 C EN 1434 Approved TECHNICAL DATA AND DIMENSIONS BTU 0014 BTU 0030 BTU 0070 BTU 0130 BTU 0400 mm 82 88 129 137 5 180 in 3 23 3 46 5...

Page 6: ...2 0 1 5 1 0 0 5 0 0 0 120 V Temperature output signal Tmax Peak temperature Selection of flow sensor to minimise pressure drop at 1 cSt 1 10 100 1000 0 1 0 1 1 10 100 1000 0 0145 0 1450 1 4504 14 5038...

Page 7: ...0 05 0 06 0 08 0 1 0 2 0 3 0 4 0 5 0 6 p bar 0 029 0 015 0 044 0 058 0 073 0 087 0 116 0 15 0 29 0 44 0 58 0 73 0 87 1 16 1 5 2 9 4 4 5 8 7 3 8 7 psi 0 3 0 4 0 6 0 8 1 1 2 1 5 2 3 4 5 6 8 10 12 15 20...

Page 8: ...ensor Ex Tank temp Under no circumstance should power be applied to these terminals Permanent damage to the controller s circuitry may result 5 Triac Output Pins 5 2 This input is to send a triac outp...

Page 9: ...7 R C L N 120 VAC 24 V AC Ground DEVICE WIRING Standard Heat Meter Installation Ensure the R and W wires from each unit are hooked up to the same corresponding wire Do not cross wire...

Page 10: ...ensor Zone Valve Pump Sensor 8 4 1 5 9 12 14 13 REL 2024 HBX 8 4 1 5 9 12 14 13 REL 2024 HBX Heat Meter Installation with Optional Setpoint Output and Sensor Wiring Ensure the R and W wires from each...

Page 11: ...ors can be installed in a horizontal or vertical position following the flow direction indicated by the arrow on the body The first length of straight of pipe connected to the flow sensor must be a mi...

Page 12: ...at Meter Installation Flow Sensor must be installed on the Return Pipe Pressure Sensor must be installed on the Supply Pipe Ground Must be grounded to Pipe Flow Sensor must be installed on the Return...

Page 13: ...he password would be 34123412 6 Once the password is input correctly then you will be taken to the main Wi Fi settings page on the phone Wait unit you get a Green check mark beside the TLBTUXXYY netwo...

Page 14: ...pp has sent all the information it will reset the SensorLinx device automatically and it will try to connect to the local building Wi Fi with the SSID and password that you had provided 14 Once the 12...

Page 15: ...d 5 The password for the device is YYXXYYXX where the XX is the first 2 digits of the device numbers and YY are the last 2 digits of the device number E g TLBTU1234 the password would be 34123412 6 On...

Page 16: ...ll connect to the TLBTUXXYY device and send it the local network information 13 Once the App has sent all the information it will reset the SensorLinx device automatically and it will try to connect t...

Page 17: ...he password key must be 26 characters long After entering all the required information please select Device Setup The control will now establish connecting ThermoLinx to your Wi Fi network Please allo...

Page 18: ...r ex Home Office Cabin ect This is the name of the system location not the sensor you added Symbols and numbers cannot be used in location name 5 After you have entered the system location name select...

Page 19: ...serial number 4 Alarms Set alarm notification for flow temperature and pressure 5 Temperatures View temperature flow and pressure data in real time 6 System Status View Current Heat measurement and li...

Page 20: ...o the sensor and download all the current data from the app This will allow the user to see the current usage statistics of devices not connected to the server Once the button is pressed it will conne...

Page 21: ...on repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise inclu...

Page 22: ...HBX Control Systems Inc 2012 HBX Control Systems Inc 4516 112th Avenue SE Calgary AB Canada T2C 2K2 Toll Free Technical Support 1 855 410 2341...

Reviews: