32
IT 2002 Order No BA 93-66-2201 Issue 01.06.08
The digital display shows the adjusted welding time and welding current.
There is a luminous indication (LED) to the right of the display:
Yellow –
lights if the welding gun button is triggered
Yellow –
lights if there is electrical contact between welding element
and workpiece
Red
– on, power unit is locked
•
after welding, until there is electrical contact with the
workpiece
Green –
on, power unit is ready for welding
Red
– on, power unit is locked
•
if the power unit is overheated (displays show 8888 and
LED lights).
After a short cooling period, the work can continue.
Red
– on, power unit is locked
•
if the power unit is overheated
•
if there is a malfunction of the power unit
Green –
lights, automatic mode is switched on (option)
Green –
lights, shielding gas is switched on (option)
5.6.1
Adjusting the Welding Time
Set the welding time (digital display
) with the arrow keys
( longer – shorter) on the display.
5.6.2 Adjusting the Welding Current
Set the welding current (digital display
) with the two arrow keys
( higher – lower) on the display.
Summary of Contents for 93-66-2201
Page 1: ...IT 2002 Power Unit 93 66 2201 Operating Manual...
Page 8: ...viii IT 2002 Order No BA 93 66 2201 Issue 01 06 08...
Page 45: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 45 Power unit type IT 2002 93 66 2201...
Page 47: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 47 Basic set up complete IT 2002 88 16 268...
Page 49: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 49 Front assembly complete IT 2002 88 16 269023...
Page 53: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 53 Country module USA complete IT 2002 88 17 930...
Page 56: ...56 IT 2002 Order No BA 93 66 2201 Issue 01 06 08 8 3 Circuit Diagram...
Page 65: ...IT 2002 Order No BA 93 66 2201 Issue 01 06 08 65 Service Support...
Page 69: ......