38
IT 1002 Order No. BA 93-66-1202 Issue 01.06.08
5.8
Checking the Quality of the Weld
You can check the quality of the weld by means of a visual inspection and a bending
test.
See also actual standards in the appendix “Arc stud welding of
metallic materials“, in section irregularities and corrective
actions.
5.8.1 Visual Inspection
A visual inspection must be carried out with each welding element.
Shape, size, evenness, and color of the weld collar are assessed during a visual
inspection. The length of a welded element should be 2 - 3 mm shorter than before
welding.
Condition
Possible cause
Corrective actions
Weld collar evenly, shiny, and complete
Length of w elding element w ithin tolerance
after w elding
- Correct parameters
- None
Contraction of w eld collar
- Plunging depth or lift too low
- Increase plunging depth, check lift and
centering of the ceramic ring
w elding element too long
- Welding energy too high
- Ceramic ring not centered correctly
- Decrease current and/or time
- Check centering
Weakly developed, uneven w eld collar w ith
mat surface
- Welding energy too low
- Increase current and/or time
Welding element too long
- Ceramic ring is humid
- Rebake ceramic rings in a furnace
Single-sided w eld collar
- Arc blow effect
- See arc blow effect
Undercut
- Ceramic ring not centered correctly
- Check centering
Weld collar low , shiny surface w ith many
spatters
- Welding energy too high
- Decrease current and/or time
Welding element too short
- Plunging speed too high
- Adjust plunging depth and/or damping factor
Visual Inspection
Summary of Contents for 93-66-1202
Page 1: ...IT 1002 Power Unit Ceramic Gas Version 93 66 1202 Operating Manual...
Page 8: ...viii IT 1002 Order No BA 93 66 1202 Issue 01 06 08...
Page 51: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 51 Power unit IT 1002 93 66 1202...
Page 55: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 55 Supply module complete IT 1002 88 17 997...
Page 59: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 59 Terminal plate complete IT 1002 88 18 013...
Page 61: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 61 Power unit complete IT 1002 88 17 929...
Page 62: ...62 IT 1002 Order No BA 93 66 1202 Issue 01 06 08 8 3 Electrical Circuit Diagram...
Page 71: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 71 Service Support...
Page 75: ......