IT 1002 Order No. BA 93-66-1202 Issue 01.06.08
31
5.3
Welding Preparation
Read the safety instructions in chapters 1, 3, and 5.
Observe the workplace requirements (chapter 3, ”Starting-up").
Check all cables and connections for proper condition.
Replace immediately defective cables and cable connections to avoid electrical
shocks.
Check the chuck for proper seat (see operating manual of according welding
gun).
Before welding, make sure that the bellows are checked for damage and proper
seat.
5.4
High-strength Welds
The following must be removed both from the weld zone and the ground clamp
connection areas:
– paint, oil and any other impurities,
– rust,
– non-conductive coatings from surface treated workpieces.
Weld to smooth and flat surfaces only.
For welding to pipes or punched plates consult our responsible
application manager (address of customer service see page ii).
5.5
Determination of Welding Parameters
The adjustment of welding parameters on the power unit (e.g. welding time) or on the
welding gun (e.g. lift) depends amongst others on
– material of the welding element
– diameter of the welding element
– material of the workpiece
The guidelines should be verified by test welding on the actual material and be
changed if necessary. For an assessment of welding results, see sections 5.8 and 5.9.
Summary of Contents for 93-66-1202
Page 1: ...IT 1002 Power Unit Ceramic Gas Version 93 66 1202 Operating Manual...
Page 8: ...viii IT 1002 Order No BA 93 66 1202 Issue 01 06 08...
Page 51: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 51 Power unit IT 1002 93 66 1202...
Page 55: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 55 Supply module complete IT 1002 88 17 997...
Page 59: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 59 Terminal plate complete IT 1002 88 18 013...
Page 61: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 61 Power unit complete IT 1002 88 17 929...
Page 62: ...62 IT 1002 Order No BA 93 66 1202 Issue 01 06 08 8 3 Electrical Circuit Diagram...
Page 71: ...IT 1002 Order No BA 93 66 1202 Issue 01 06 08 71 Service Support...
Page 75: ......