40
Z30A
HBM
A2076-1.0 de/en
HBM has already specified the
Bridge Sensor
template for the Z30A for a
trandsucer.
Additional templates such as the
Signal Conditioning
template can be
specified by the user.
Area 4:
The actual user can modify the last of these areas with, for instance:
- a short comment in text form,
- filter settings,
- zero value.
Example:
Content specified by HBM on the individual test report: Area 3 of the
Z30A/2kN sensor, ID no. 123456, produced 2006-06-01 by HBM.
Template: Bridge Sensor
Parameter
Value
1)
Unit
Change
requires
rights to
level:
Explanation
Transducer Electrical
Signal Type
Bridge
Sensor
ID
Minimum Force/Weight
0.000
N
CAL
The physical measured quantity and
unit are defined when the template
Maximum Force/Weight
2.000k
N
CAL
unit are defined when the template
is created, after which they cannot
be changed.
Minimum Electrical
Value
0.00000m
V/V
CAL
The difference between these
values is the sensitivity according to
Maximum Electrical
Value
-2.00078m
V/V
CAL
values is the sensitivity according to
the HBM test certificate (tensile
force) and from calibration
1)
.
Mapping Method
Linear
This entry cannot be changed.
Bridge type
Full
ID
In connection with the bridge type,
the following values are available for
selection: ”Quarter” for quarter
bridge, ”Half” for half bridge, ”Full”
for full bridge. Some HBM
transducers can be connected as
half bridges or full bridges according
to choice. For SG-based
transducers from HBM the bridge
type is always full bridge.
Impedance of each
bridge element
700.0
Ohm
ID
Input resistance according to the
HBM data sheet.
Response Time
1.0000000u
sec
ID
Of no significance for HBM
transducers.
Excitation Level
(Nominal)
5.0
V
ID
Nominal excitation voltage
according to the HBM data sheet.