10
VKIA405
HBM
A2448-1.1 en/de/fr
4
Preparing the cables
For optimum results, proceed as follows:
•
Remove the outer sheath of the cable and depending on the cable diameter,
expose the braided screen for about 10 ...15 mm.
•
Push the cap nut and the bladed insert with the sealing ring onto the cable.
•
Bend the braided screen outward at right angles (90
°
).
•
Crimp the braided screen over towards the outer sheath of the cable, i.e. fold
it a further 180
°
.
•
Slip the intermediate connection piece on as far as the braided screen, quickly
turning it to and fro around the cable axis.
•
Push the bladed insert with the sealing ring into the intermediate connection
piece and engage the locking element.
•
Firmly tighten the cap nut.
Shielded cable
Cap nut
Sealing ring
Bladed insert
Braided screen
Intermediate connection piece
Fig. 4.1:
Screwed clamping gland assembly