MP85A(DP) FASTpress, MP85A(DP)
−
S EASYswitch
24
A2073-5.0 en/de/fr
Operating state:
LED1 (OK / NOK)
LED 1 (OK/NOK) / Process status
Red LED
Yellow
LED
Green
LED
Flashing LED
Initialization after device is switched on
x
Alarm
x
x
Process is started
x
x
Total result OK
x
Overall result NOK
x
LED2 (Status)
LED2 (Status) / Device status
Red LED
Yellow
LED
Green
LED
Flashing LED
Initialization after device is switched on
x
One of the following errors is present:
EEPROM error, initial calibration error, scal-
ing error, MMC/SD error or CAN bus error
x
Transducer error, ADC overflow or gross
overflow (one or both measurement chan-
nels)
x
x
LCD error
x
x
CAN bus: Transmit / receive data
x
x
Status “Pre-operational”
x
Status “Operational”
x
MP85ADP PROFIBUS status
Red LED
Yellow
LED
Green
LED
Flashing
LED
Error state
x
BD_SEAR, WT_PARM, WT_CONF states
x
DATA_EX status
x
Control LEDs for the Ethernet status are located underneath the MP85A pro-
cess controller.
LED Ethernet status
Green LED
Yellow LED
Physical connection present
−
on
Transmit / receive data
−
flashing
100 MBit transmission speed
on
−
10 MBit transmission speed
−
on or flashing