Safety instructions

Use in accordance with the regulations

The ML71BS6 CAN bus module is to be used exclusively for measurement
tasks and directly related control tasks. Use for any purpose other than the
above shall be deemed to be not in accordance with the regulations.

To ensure safe operation, the device may only be operated in accordance with
the information given in the Operating Manual. It is also essential to comply
with the legal and safety requirements for the application concerned during
use. The same applies to the use of accessories.

General dangers of failing to follow the safety instructions

The ML71BS6 CAN bus module complies with the state of the art and is
fail-safe. The device may give rise to further dangers if it is inappropriately
installed and operated by untrained personnel.

Any person instructed to carry out installation, commissioning, maintenance or
repair of the device must have read and understood the Operating Manual
and in particular the technical safety instructions.

Remaining dangers

The scope of performance and supply of the ML71BS6 only covers part of the
range of measurement technology. In addition, equipment planners, installers
and operators should plan, implement and respond to the safety engineering
considerations of measurement technique in such a way as to minimise
remaining dangers. Prevailing regulations must be complied with at all times.
There must be reference to the remaining dangers connected with
measurement technique.
In this manual, the following symbols are used to draw your attention to any
remaining dangers that might occur when working with the ML71BS6:

Symbol:

WARNING

Meaning:  Dangerous situation

Warns of a potentially dangerous situation in which failure to comply with
safety requirements can lead to death or serious physical injury.

Summary of Contents for ML71BS6

Page 1: ...A0851 3 1 en MGCplus Measuring amplifier system CAN bus interface ML71BS6 Operating manual...

Page 2: ......

Page 3: ...Front panel 8 4 Parameterization 9 4 1 Settings CAN1 CAN2 9 4 1 1 Panel output signals CAN 1 11 5 Menu structure in set up mode 13 6 CAN protocol 14 6 1 Measurement signal transmission 14 6 1 1 Absolu...

Page 4: ...untrained personnel Any person instructed to carry out installation commissioning maintenance or repair of the device must have read and understood the Operating Manual and in particular the technical...

Page 5: ...71BS6 CAN bus module may be carried out without our express agreement Any modification shall exclude all liability on our part for any resulting damage In particular any repair or soldering work on mo...

Page 6: ...s per CAN port scales them and outputs them at the CAN bus Two independent CAN interfaces per channel and two different physical layers ISO 11898 24V and a low speed link based on the Philips TJA1053...

Page 7: ...systems female connectors CAN1 and CAN2 Both the CAN interfaces are used to output the MGCplus measurement data Each of the interfaces can be assigned up to 128 measured values Connectors male CAN1 CA...

Page 8: ...LED caption Colour Meaning in Status mode CHAN yellow Channel selected ERROR WARN red error warning Rx1 not used Tx1 OVRN1 red yel low CAN protocol transmitted BUSERR1 red Bus error at CAN1 Rx2 yellow...

Page 9: ...note that the maximum possible output rates can only be achieved if no signals have been selected at CAN port1 If a selected rate cannot be achieved the messages will be output as quickly as possible...

Page 10: ...D Last ID Reset CAN1 port 640 641 Fig 4 1 CAN1 CAN2 dialogue window 2 Use the cursor keys to choose the baud rate selection field Use to call the selection list and choose the desired baud rate Confir...

Page 11: ...signal 1 System Display Parameters Options Gross Source for MGC channel Signal CAN signal 1 CAN signal 2 CAN signal n Gross Net Store1 Store2 Combined PV 8 Fig 4 2 CAN1 CAN 2 output signals dialogue w...

Page 12: ...e window 2 Use the cursor keys to select the Source for MGC channel selection field Use to call the selection list and choose the desired signal Confirm with 3 Use the cursor keys to select the MGC ch...

Page 13: ...uring the initial start up or for a new measurement task User defiened dis play settings such as the required method of representing va lues function key as signment or the spe cification of channel n...

Page 14: ...6 1 1 Absolute values in Float In each 8 byte CAN message 2 signals are transmitted as Float values 32 bit This is dealing with scaled measured values 6 1 2 In digits as Long In each CAN message 2 of...

Page 15: ...red value 1 signed in tegers in digits from 30000 Measurement data messages CAN port 2 Absolute values in Float Identifier 8 byte data field 0x300 0x33F 4 byte measured value 1 absolute Float 4 byte m...

Page 16: ...ue 2x 9 pin DSUB individual potential separation of supply and ground Measurement recording Number of signals at 1 Mbaud 11 bit Format INT16 Signals 1 8 Hz Output rate 2400 9 16 1200 17 24 800 25 32 6...

Page 17: ...rd format mm Europe 100 x 160 Width mm 20 3 4 divs Receptacle DIN 41612 indirectly Analogue output The analogue output can display one of the max 128 input signals at a time Nominal rated voltage V 10...

Page 18: ...18 MGCplus ML71BS6 A0851 3 1 en HBM...

Page 19: ......

Page 20: ...D 64293 Darmstadt Tel 49 6151 803 0 Fax 49 6151 8039100 Email support hbm com Internet www hbm com Modifications reserved All details describe our products in general form only They are not to be und...

Reviews: