Mounting
10
A1140-4.0
HBM: public
HLCM…
S
As protection against welding currents that can dam
age the electronic parts of the load cell, it is recom
mended that the EEK4 grounding cable is used.
S
In load cells with an additional outer braided wire over
the cable (item no. K-HLCM with option B2, together
with codes 3R, 6R or 12R), this cable is only used for
protection against increased mechanical stress (e.g.
damage caused by gnawing rodents). To avoid acci
dental energization, the outer braided wire has to be
connected to potential equalization at least once. This
outer braid is not used to shield the load cell. The
inner braid of the load cell cable is used for shielding.
Information
If the load cell is to be replaced, the upper module plate
can be lifted by max. 1.5 mm.
Lock the nut in place to hold the upper module plate in
this position. Dismounting the tank itself is not required.
When replacing the load cell, the following tightening
torques of the fastening screws must be considered
110 kg - 2.0 t
electrogalvanized
130 N
V
m
stainless
90 N
V
m
2.2 t - 4.4 t
electrogalvanized
400 N
V
m
stainless
400 N
V
m
Summary of Contents for HLCM Series
Page 1: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais HLCM...
Page 3: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais HLCM...
Page 24: ...Specifications of the load cells HLCB 22 A1140 4 0 HBM public HLCM...
Page 25: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais HLCM...
Page 47: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais HLCM...