Sensor Installation
FS64
A4263-3.5
HBM: public
17
followed strictly. On the following scheme there is the
order in which locking screws should be removed.
To be unfastened only
(non-removable screw)
To be unfastened only
(non-removable screw)
To be unfastened and
removed (removable screw)
To be unfastened only
(non-removable screw)
To be unfastened only
(non-removable screw)
To be unfastened and
removed (removable screw)
Fig. 2.7
1
Any unlocking action should only be performed after
complete fixation of the sensor on the surface.
Throughout the next steps, it is advisable to control both
FBG wavelength changes.
Connect the sensor to an interrogator and control the
Center Wavelengths of the two FBGs so that their differ
ence is as close as possible to the value shown on the
calibration sheet (number 1 on