Electrical connection
C16i
A05516_01_Y00_01
HBM: public
17
5.1
Bus wiring of several load cells
The bus wiring of several load cells come into being by joining together the
connection cables' core ends with identical colors. HBM recommend the use of
a junction box without dropping resistors (e.g. VKD2R-8).
UB
GND
RB (RX+)
RA (RX-)
TB (TX+)
TA (TX-)
white
red
grey
green
black
blue
GND
UB
RB (RX+)
RA (RX-)
TB (TX+)
TA (TX-)
GND
UB
RB (RX+)
RA (RX-)
TB (TX+)
TA (TX-)
Converter
(SC232/422B)
PC
C16i ...
C16i ...
RS-232
RS-485 / 4-wire BUS
white
red
grey
green
black
blue
Fig. 5.1
Wiring code
5.2
Power supply
The load cell features a digital output with RS-485 (4-wire) interface. For the
power supply a DC supply voltage is required.
Power supply unit selection for C16i...
Procedure for selecting a suitable power supply unit to supply power to the in
terface converter and the connected C16i... load cells:
1. Determine the required cable length between power supply unit and junction
box by examining the actual on site situation.
2. In the table below, read off actual power consumption values in relation to
the number of load cells used.
3. Select cable cross-section in the relevant line such that the required cable
length can be implemented. With a 15 VDC nominal voltage, it is always
Summary of Contents for C16i series
Page 1: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 3: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 28: ...Dimensions 26 A05516_01_Y00_01 HBM public C16i...
Page 29: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 56: ...Abmessungen 28 A05516_01_Y00_01 HBM public C16i...
Page 57: ...Mounting Instructions Montageanleitung Notice de montage English Deutsch Fran ais C16i...
Page 83: ...Dimensions C16i A05516_01_Y00_01 HBM public 27...