Z6/M
CONNECTION
12
8
CONNECTION
The load cells on weighing modules can be connected to:
S
Carrier‐frequency measuring amplifiers or
S
DC meas. amplifiers suitable for strain‐gage based measurement systems.
The wiring assignment of the load cell is shown in
(white)
(black)
(gray)
Feeding (+)
(green)
(red)
(wire strand)
Feeding (-)
Sense (-)
Sense(+)
(blue)
Sense(+)
Signal (-)
Shield, filler connected with housing,
in the case of type Z6F and Z6G load
cells
Fig. 8.1
Wiring assignment of the load cell (six‐wire circuitry)