HBE SOFTEX Operating And Mounting Instructions Manual Download Page 9

Solutions for Fluid Technology

HBE GmbH

Hönnestraße 47 | 58809 Neuenrade | Germany

Phone +49 (0) 23 94 / 616-0
Fax  +49 (0) 23 94 / 616-25

[email protected]
www.hbe-hydraulics.com

Afterwards, the user has to fit a coupling protection con-
sisting of a fixed cover. The cover is intended to protect 
the coupling especially from falling items. The covers can 
be provided with regular openings. Following dimensions 
must not be exceeded.

The  distance  of  the  cover  to  rotating  parts  must  be  at 
least 5 mm. The cover must be electrically conductive and 
must be included in the potential equalisation. The cover 
is only allowed to be taken off during a halt. Aluminium 
bellhousings (also with damping flange) are permitted as 
connecting  element,  if  the  content  of  magnesium  is  less 
than 7.5 %.

CAUTION! 
When  mounting  the  coupling  to  machines  of  cate- 
gory  2D,  please  ensure  that  there  is  no  dust  be-
tween  cover  and  coupling.  The  couplings  must  not 
operate in dust particles. When using the coupling 
in machines of group I, category M2, the cover must 
not consist of light metal (higher mechanical load).

During operation of the coupling please pay attention to:

 Changed operation noises

 Occurring vibrations

ATTENTION! 
In case of changes or irregularities during the opera-
tion of the coupling, the power unit must be switched 
off immediately. The cause of the disturbance must 
be found out by the check list ”Trouble in service” 
and be removed, if possible.

ROUND 

OPENINGS

Ø 

mm

RECTANGULAR 

OPENINGS

SIDE LENGTH

 mm

TOP OF COVER

4

4

SIDE OF COVER

8

8

6.6 TROUBLE IN SERVICE / CAUSES AND CLEARANCE

A disturbance by break of the fixing screws of the flange  
couplings  must  be  excluded  under  observance  of  the  
selection criteria.

DISTURBANCES 

CAUSES

INDICATIONS OF 

RISKS FOR HAZARDOUS 

AREAS

CLEARANCE

Changes of 

running noises 

Vibrations

Alignment fault

High temperatures 
at the surface lead to 
an ignition risk

• Stop the unit
• Check and remove changes in construction
• Check the drive unit for damages
• Check and correct, if necessary, alignment and dimension 
  E of the coupling
• Check the wear of the gear ring and exchange, 
  if necessary

Loose screws for axial 
securing of the hub

Ignition risk by hot surface 
and sparking

• Stop the unit
• Check and correct alignment and dimension E of the 
  coupling
• Check the wear of the gear ring and exchange, 
  if necessary
• Retighten the fixing screws by the starting torque and 
  protect it from self-loosening with Loctite

Summary of Contents for SOFTEX

Page 1: ...t of the shafts to be connected as well as expansions will be compensated The operating temperatures are between 50 C and 120 C depending on the type of gear ring Short term temperature peaks up to 15...

Page 2: ...5 75 93 126 50 26 3 20 40 46 M8 20 20 M10 48 60 310 525 655 19 48 50 60 105 85 103 140 56 28 3 5 21 45 51 M8 20 30 M10 55 70 375 625 825 22 55 60 70 120 98 118 160 65 30 4 22 52 60 M10 20 25 M12 65 75...

Page 3: ...s concerning security Item 6 This operating and mounting instruction is part of the delivery extent and must be kept carefully Tightening torque for the fixing screws DIN 912 10 9 3 2 WARNING AND INDI...

Page 4: ...months at a dry place The gear rings Polyurethane keep their qualities in case of a corresponding storage for approx 5 years ATTENTION It must be ensured that there is no condensation in the storage r...

Page 5: ...the shaft DANGER In order to avoid burnings by the contact with ted hubs please wear safety gloves CAUTION Please pay attention to the danger of ignition in hazardous areas ATTENTION When mounting the...

Page 6: ...s s Axial Misalignment Radial Misalignment Misalignment of Angle TYPE DIMENSIONS mm AXIAL MISALIGNMENT KA mm RADIAL MISALIGNMENT KR mm MISALIGNMENT OF ANGLE KW SPEED1 1 MIN SPEED1 N 1 MIN L E b s 750...

Page 7: ...elastic gear ring must be put to test visual check torsion test In case of an unessential or no wear of the gear ring during first check the check cycles can be set to an operating time of 4000 h or 1...

Page 8: ...on groups IIB and IIA as well as the tempe rature ranges T3 T1 are included in the identification mark II 2G c IIC T4 X 6 5 COMMISSIONING Bevor commissioning of the coupling following checks and possi...

Page 9: ...g please pay attention to Changed operation noises Occurring vibrations ATTENTION In case of changes or irregularities during the opera tion of the coupling the power unit must be switched off immedia...

Page 10: ...g Check the shafts and feather keys for damages Check the operating parameter and choose a harder gear ring or bigger coupling Check the mounting space when deciding for a bigger coupling Mount the co...

Page 11: ...remove the source of heat Exchange the gear ring Check and correct if necessary alignment and dimension E of the coupling Tighten the fixing screws with tightening torque and protect it from self loos...

Page 12: ...Softex Elastic Couplings are non electric devices acc to the EG rules 94 9 EG and meet the security and healthy prescriptions for the conception and the construction of the device concerning the inte...