17
HAZET-WERK
Hermann Zerver GmbH & Co. KG
;
Güldenwerther Bahnhofstraße 25 - 29 • 42857 Remscheid • GERMANY
[
+49 (0) 21 91 / 7 92-0 •
\
+49 (0) 21 91 / 7 92-400 •
^
hazet.de •
]
Immer persönliche Schutzausrüstung tragen!
Always wear personal protective equipment!
• Never clean with solvents or acids, esters
(organic compounds comprising acids
and alcohol), acetone (ketone), chlorinated
hydrocarbons or oils containing nitro hydro-
carbons. Do not use any chemicals with a
low burning point.
• For customer service, please contact your
distributor or the HAZET Service Centre.
5. Malfunctions
If faults occur, check the following:
• Compression system and compressed air
supply line, air requirement l/min and hose
diameter according to the technical data of
the tool
• Check the compressed air for the occur-
rence of dust, condensate and rust particles
• Excess lubrication of the air motor
4. Maintenance and care
Lubrication:
• Air tools must be oiled for their entire lifetime.
The motor and the ball bearings require
compressed air to operate the tool. Since
the moisture in the compressed air corrodes
the motor, the motor must be lubricated
every day. We recommend that an inte-
grated lubricator is used to do this.
• HAZET 9070N-1 lubricator for mounting to
the pneumatic tool.
• Lubricating the pneumatic motor by hand:
Disconnect tool from the air supply and hold
with the air inlet pointing upwards. Put 1 or
2 drops of special pneumatic oil into the air
inlet.
• Connect the tool to the compressed air sup-
ply; cover the air outlet on the tool with a
towel and operate for a few seconds.
• Never use combustible or easily evaporable
liquids such as kerosene, diesel or petrol to
lubricate the tool.
CAUTION!
Excess oil in the motor will be
expelled through the air outlet.
WARNING!
Never point the opening of the outlet
at any person or object. The air outlet
is located at the striking head.
Maintenance
• Always disconnect the tool from the com-
pressed air supply prior to carrying out
maintenance work.
• If used daily, carry out maintenance every
3 months, or every 1000 operating hours at
the latest.
• Damaged or worn components such as
O-rings and bearings, etc. must be replaced
and all moving parts must be lubricated.
• Only use spare parts recommended by the
manufacturer, as any other parts will invali-
date any express or implied warranty.
• Ensure that the relevant environmental pro-
tection regulations are observed when dis-
posing of individual parts, lubricants and
oils, etc.
3