WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump
™
Series ___________________ ______________________________Page 10 of 15
Seal Installation
(See Parts Diagram on page 11 of this manual for pump component locations.)
8.
Clean and lightly lubricate the impeller hub and seal recess in the seal plate with a dilute solution of non-
granulated liquid-type soap.
9.
Gently wipe the black, polished surface of the spring seal assembly with a clean, soft, cotton cloth. Press the
spring seal assembly onto the
impeller
hub – black polished surface facing away from the impeller.
10.
Gently wipe the polished surface of the ceramic seal with a clean, soft, cotton cloth. Lubricate the rubber cup
on the ceramic seat and press it firmly and evenly into the recess of the
seal plate
– polished side facing out.
Replacing the Impeller and Diffuser
(See Parts Diagram on page 11 of this manual for pump component locations.)
11.
Place the
seal plate
onto the
motor mounting plate
, aligning the tabs on the
seal plate
with the grooves on the
motor mounting plate
.
12.
Screw the
impeller
onto the motor shaft in a clockwise direction. Tighten snugly by holding motor shaft with
wrench as noted in step #4.
13.
Place the
diffuser
over the
impeller
onto the
seal plate
fitting positioning lug between the two (2) guides.
Replacing the Motor Assembly
(See Parts Diagram on page 11 of this manual for pump component locations.)
14.
Fasten motor end cover by using the two (2) hex shaped screws. Slide the motor assembly with the
diffuser
in
place, into
pump/strainer housing
, being careful not to disturb the
diffuser gasket
.
15.
Fasten assembly to
pump/strainer housing
using the four (4) 3/8”" x 2"
housing cap screws
. (Be sure
housing gasket
is in place, and replace if damaged). Tighten alternately and evenly.