30
6. APPENDICES (continued)
6.4 Troubleshooting guide
Fault
Error codes
Description
Solution
Water inlet sensor fault
P01
The sensor is open or has
short-circuited.
Check or replace the sensor.
Water outlet sensor fault
P02
The sensor is open or has
short-circuited.
Check or replace the sensor.
Outside temperature sensor
fault
P04
The sensor is open or has
short-circuited.
Check or replace the sensor.
De-icing sensor fault
P05
The sensor is open or has
short-circuited.
Check or replace the sensor.
High pressure protection
E01
Refrigerating circuit pressure
too high or water flow too low
or coil obstructed or air flow
too weak.
Check the high pressure switch
and the refrigerating circuit
pressure.
Check the water or air flow.
Check the flow controller is
working properly.
Check that the water inlet/outlet
valves are opening.
Check the by-pass settings.
Low pressure protection
E02
Refrigerating circuit pressure
too low or air flow too weak or
coil obstructed.
Check the low pressure switch
and the refrigerating circuit
pressure to see if there is a leak.
Clean the coil surface.
Check the fan rotation speed.
Check the free circulation of air
through the coil.
Flow sensor fault
E03
Insufficient water flow or
sensor short-circuited or faulty
Check the water flow, check the
filtration pump and flow sensor
for any faults.
Temperature difference too
great between the outlet and
inlet water
E06
Insufficient water flow volume,
water pressure difference too
low/too high.
Check the water flow or for a
system obstruction.
Communication problem
E08
LED controller or PCB
connection fault.
Check the wiring.
Level 1 antifreeze protection
E19
Air and inlet water temperature
too low.
Turn off the heat pump and drain
the capacitor. Freezing risk.
Level 2 antifreeze protection
E29
Air and inlet water temperature
even lower.
Turn off the heat pump and drain
the capacitor. Freezing risk.
Antifreeze protection air side
EC
Certain operations must be performed
by an approved engineer.
Summary of Contents for Powerline EcoPac 81502
Page 2: ...POMPE A CHALEUR POUR PISCINE Manuel d instructions et d installation ...
Page 25: ...22 6 ANNEXES suite 6 3 Vues éclatées et pièces détachées 81502 34 ...
Page 27: ...24 6 ANNEXES suite 81512 ...
Page 29: ...26 6 ANNEXES suite 81522 35 ...
Page 31: ...28 6 ANNEXES suite 81542 39 ...
Page 35: ......
Page 36: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...
Page 59: ...22 6 APPENDICES continued 6 3 Exploded view and spare parts 81502 34 ...
Page 61: ...24 6 APPENDICES continued 81512 ...
Page 63: ...26 6 APPENDICES continued 81522 35 ...
Page 65: ...28 6 APPENDICES continued 81542 39 ...
Page 69: ...UNIDAD DE BOMBA DE CALOR PARA PISCINAS Manual de Instalación e Instrucciones ...
Page 92: ...22 6 ANEXOS continuación 6 3 Vistas detalladas y piezas sueltas 81502 34 ...
Page 94: ...24 6 ANEXOS continuación 81512 ...
Page 96: ...26 6 ANEXOS continuación 81522 35 ...