USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
Alarm Cable and Alarm Module Wiring
As shown below, the one side of the Power Splitter will plug into the PoolScout Alarm Cable. The
Alarm Cable power connector will come prewired to the RED and BLK conductors. In addition to
the power connector, there are two additional conductors (WHT and YEL) that must be wired to the
camera’s alarm connector. With the cover removed, connect the 4 conductors of the Alarm Cable to
the screw terminal block inside of the Alarm Module as shown below. Route the Alarm Cable from
the back of the Alarm Module according to the diagram.
Carefully coil excess wire into the Electrical Box and fasten the cover using the original hardware.
The camera can now be mounted onto the Electrical Box cover.
PoolScout Alarm Module
With the Alarm Cable connected, you can now mount the Alarm Module. Mount the alarm in the
desired location. If the included hardware is not suitable for the mounting surface, use appropriate
hardware purchased separately. Route the Alarm Cable in manner where it will not get pinched
when the Alarm Module is fastened.
Alarm
Cable
4 3 2 1
ALARM
YEL
&
RED
BLK
WHT
1 2 3 4
4 3 2 1
ALARM
4 3 2 1
1 White
2 Yellow
3 not used
4 not used
1 Yellow & Red
2 Black
3 not used
4 White
Power
Splitter
Alarm Connector