Electrical Box
After drilling the access hole, remove the Electrical Box cover and rear knockout. Center the box
over the hole to test fit. Position the exit fitting (used for Alarm Module wiring) where desired. If
satisfied, spread caulk around the outside back of the Electrical Box, leaving a small space at the
bottom for water to run out. Fasten the Electrical Box using the included hardware. If the hardware
is not suitable for the mounting surface, use appropriate hardware purchased separately.
With the cover off, test fit the Power Splitter cable inside of the Electrical Box and run the 4 con-
ductor end of the Alarm Cable out of the Electrical Box exit fitting. This should give you an estimate
of where the Alarm Module can be mounted (within approximately 3 feet of the camera).
Connections inside of the Electrical Box
The connections shown below will be made inside of the Electrical Box. Refer to the diagram and
the following sections in this manual.
Ethernet Cable
Plug one end of the 100’ ethernet cable into a LAN port on the home network’s router or access
point. Route the other end to the access hole and into the Electrical Box. Plug the ethernet cable
into the camera’s ethernet jack. Because this connection will be housed within the Electrical Box,
the watertight cover on the camera’s ethernet jack can be removed and discarded. You may need
to coil up excess cable indoors before permanently installing at the Electrical Box. When routing is
complete, secure the cable along the run using the supplied cable clips.