Connecting the Phantom Cleaner To Pool
6
Installing Universal Wall Fitting
Builders:
Install the Dedicated Return Line at the
midpoint of the pool’s long wall.
S p e c i f i c a t i o n
: D e d i c ated Return Line in Pool Wa l l .
D e p t h :
At least 6 inches below water level.
S i z e :
1-1/2 inch NPT Female T h r e a d e d .
1 .
Flush plumbing lines before proceeding.
2 .
Turn Booster Pump and Main Filtration Pump
O F F
.
3 .
Remove plug or existing Universal Wall Fitting from
p r e v i o u s ly installed pool cleaner (if any ) .
4 .
Remove the Universal Wall Fitting (part O) and Te fl o n
®
t ape
from Bag #1.
5 .
When installing or re-installing the Universal Wall Fitting
use Te fl o n
®
t ape on its plastic threads. L e ave two starting
threads on the end of the Universal Wall Fitting un-tap e d .
6 .
Screw the Universal Wall Fitting into the Dedicated
Return Line.
I m p o r t a n t :
Turn the Universal Wall Fitting 1 full turn to the
right to engage starting threads. Be sure both parts are
started properly (not cross threaded) then resume tightening
– hand tighten only. The Universal Wall Fitting may not screw
all the way into the Dedicated Return Line.
Do not over tighten.
Te fl o n
®
is a registered trademark of E.I. du Pont de Nemours
and Company.
Assembling and Sizing the Rigid Pressure Hose
Assembling and Sizing the Rigid Pressure Hose
1 .
Open the plastic bag labeled #1 that contains 10 Rigid Hose
Pipes (Part N) and 5 Hose Pipe Couplings (Part
I
) .
2 .
L u b r i c ate the 5 Hose Pipe Couplings by dunking them in
s o apy wat e r.
3 .
Align the Barbs on the Hose Pipe Coupling with the Tabs on
the Rigid Hose Pipes and snap together. Be sure the black
o-ring does not slip out of the groove on the Hose Pipe
Coupling (if the o-ring is visible through the latch opening
when pipes are snapped together the o-ring has slipped out
of the groove and will leak)
4 .
Make 5
S e t s
of
Pipe Assemblies
by connecting 1 Rigi d
Hose Pipe onto each end of the Hose Pipe Couplings.
5 .
L o c ate the “Measuring Tap e ” (packed in Bag #1), secure the
end of the tape marked “ Wall Connector End” on the pool
coping immediat e ly above the Universal Wall Fitting.
6 .
Unroll the Measuring Tap e , walk around the pool to the
farthest point along the pool wall from the Universal Wa l l
F i t t i n g .
At the farthest point from the Universal Wall Fitting hold
the Measuring Tape at the pool edge/coping and read the
number of Pipe Assemblies specified on the tap e .
Universal Wall Fitting
Rigid Hose Pipe Assembly
Dedicated Return Line
Universal Wall Fitting (O)
Measuring Ta p e
Connecting Hose Pipes
I
N
a .
N o t e :
If the measuring tape specifies more than 5 Pipe
A s s e m b l i e s , you need to purchase the additional Pipe
sections (P/N AX6000HE) from your Authorized Hay w a r d
D e a l e r.
b . If the measuring tape specifies fewer than 5 Pipe
A s s e m b l i e s , set the remaining Pipe Assemblies aside you
won’t need them.
R e c t a n g u l a r-Shaped Po o l
Kidney-Shaped Po o l
Angle-Shaped Po o l
Universal Wall Fitting
(Dedicated Line)
Universal Wall Fitting
(Dedicated Line)
Farthest Point
Farthest Point
Universal Wall Fitting
(Dedicated Line)
Farthest Point
I
N
1 Pipe
Assembly