background image

Description

The HLIOEXPAND is an expander board accessory for all OmniLogic pool controls.  It offers four 

additional temperature sensor inputs, pool/spa valve actuator outputs and low voltage (dry con-

tract) outputs to control various pool and backyard equipment.  After installation, the OmniLogic 

will detect the HLIOEXPAND and allow you to configure the additional input/outputs to control and/

or monitor your pool and backyard equipment. 

SENSOR INPUT:

  

Use only Hayward 10k ohm thermistor type temperature sensors (not 

included).  Hayward recommends the multipurpose "PC" sensor available at 

local Hayward dealers.

VALVE ACTUATOR

OUTPUT:

   

24 VAC, 0.55 A, fuse protected 

LOW VOLTAGE DRY

CONTACT RELAY:

    24 VAC, 0.5 A max 

 

Installation

DANGER of Death, Injury or Property Damage if procedure not followed. 

This accessory 

connects to the OmniLogic panel beneath the dead front.  Dead front removal is required for this 

installation. Power to the OmniLogic panel MUST be shut off before the dead front is removed.  

This means a complete shutdown of power to the entire OmniLogic panel. 

Overview

The HLIOEXPAND is design to slide between guide rails and insert into a dedicated slot on the Om-

niLogic main board.  Once inserted, the OmniLogic will discover the HLIOEXPAND and its inputs/

outputs can be configured within the OmniLogic's CONFIGURATION WIZARD.  

There are two "locking" positions when sliding the HLIOEXPAND between the OmniLogic's guide 

rails.  The first position will hold the board in place to allow easy access to wire sensors, valves, 

and low voltage equipment.  Once all connections are made, slide the HLIOEXPAND further into the 

second position.  The HLIOEXPAND should insert firmly into the OmniLogic main board's slot and 

lock in place.  

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

2

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

2

Summary of Contents for HLIOEXPAND

Page 1: ...0 Division Street Elizabeth NJ 07207 www hayward com Input Output Expander for OmniLogic Owner s Manual HLIOEXPAND Contents Description 2 Installation 2 Configuration 6 092522 RevA USE ONLY HAYWARD GE...

Page 2: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Page 3: ...nects to the OmniLogic panel beneath the dead front Dead front removal is required for this installation Power to the OmniLogic panel MUST be shut off before the dead front is removed This means a com...

Page 4: ...Slide the HLIOEXPAND between the guide rails until it locks as shown below In this position the board will be sticking out from the enclosure allowing access to the wiring connections on the HLIOEXPAN...

Page 5: ...e when re mounting the panel After all connections have been made use wire anchors and ties to secure the bundle of wires coming from the HLIOEXPAND Two anchors with adhesive back and two nylon ties s...

Page 6: ...fficult to slide you may have to spread the guide rails slightly to release the board from position 1 2 Replace the OmniLogic deadfront and fasten 3 Restore power to the OmniLogic Position 2 Slide the...

Page 7: ...displayed in their corresponding tables They can be easily identified by looking for IO Module under Device Type in the tables as shown below Refer to the OmniLogic Installation Manual for details on...

Page 8: ...istered trademark and OmniLogic is a trademark of Hayward Industries Inc 2013 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is no...

Reviews: