NOTE: Step 1I – Heaters older
than 11/2010 – If no voltage
across R & C, remove
FC3 fuse and test for
continuity. IF open go to page
24. IF OK go to Step 1J
Disconnect the plug from P5 (on fuse board). Test
22-28VAC between R & C. IF no voltage, replace
Fuse Board (
pg. 20
). If correct, go to step 1J.
Inspect wiring
Inspect ICB wiring, ensuring all plugs are securely
fastened. IF wiring is OK go to Step 1K. IF NOT,
secure wiring/plugs then retest.
Test P5 (low voltage)
Step 1I
25
Step 1J
1. Heater Not Powering Up (cont.)
Disconnect and test the red and grey wires from
the ICB. IF 22-28VAC is present go to step 1L. IF
NOT, replace wire harness (
pg. 20
).
Test ICB input (low voltage)
Step 1K