IF inlet pressures are correct AND the
manifold pressure is high or low, go to
step 4.
*NOTE: Before any adjustment occurs, verify inlet gas pressure meets the requirement
set forth by the data plate on the heater. IF it does, continue to step 4. IF NOT, refer to
installation manual and/or contact installer.
Verify heater specifications off the heater
plate (bottom front inside heater)
17
How To: Test/Adjust Gas Pressure (cont.)
Step 3
*
Adjust the manifold pressure
(at the gas valve)
Remove plug. Once removed, increase
pressure by rotating valve clockwise,
(counter clockwise to reduce pressure).
Step 4
NOTE: IF incoming gas pressure is within range, then your manifold pressure
should be correct per factory settings.