Inspect Fuse Board wiring, ensuring all plugs are
securely fastened. IF correct, proceed to step 1F.
Test Fuses
Verify that FC1 & FC2 fuses aren’t open. Replace all
open fuses & go to
section 2
. IF correct, go to 1G.
Inspect connections
Step 1E
Step 1F
Disconnect the P3 plug from the fuse board. Test
110-125VAC between pins 1&2 and 3&4 on the
board. IF good, go to 1H. IF NOT, replace the Fuse
board (
pg. 20
).
Test transformer input
Step 1G
24
Disconnect P4 plug from fuse board. Verify 22-
28VAC between pins 1 & 2 (red wires), then 110-
125VAC between pins 4-6 (grey wires). IF correct,
go to 1I. IF incorrect replace transformer (
pg.20
).
Test transformer output
Step 1H
1. Heater Not Powering Up (cont.)