background image

 

 

 

 

Page 2

 

 

 

 

 

AVERTISSEMENT : 

TOUT LE CÂBLAGE ÉLECTRIQUE DOIT ÊTRE CONFORME AUX CODES ET RÈGLEMENTS 

LOCAUX AINSI QU’AU CODE CANADIEN DE L’ÉLECTRICITÉ (CCE). DES TENSIONS DANGEREUSES PEUVENT 
PROVOQUER DES CHOCS, DES BRÛLURES ET LA MORT OU DE SÉRIEUX DOMMAGES MATÉRIELS. POUR 
RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE, N’UTILISEZ PAS DE RALLONGE POUR RACCORDER CET APPAREIL À 
L’ALIMENTATION ÉLECTRIQUE.  

MISE EN GARDE : 

LE CIRCUIT D’ALIMENTATION DOIT ÊTRE PROTÉGÉ PAR UN DISJONCTEUR DIFFÉRENTIEL DE 

FUITE À LA TERRE. 

MISE EN GARDE 

: N’UTILISEZ PAS AVEC UN GRADATEUR. 

MISE EN GARDE 

: POUR UTILISATION EXTÉRIEURE, INSTALLEZ AU MOINS 1 PI (30 CM) AU-DESSUS DU SOL. 

AVERTISSEMENT :

 NE RACCORDEZ PAS DEUX OU PLUS DE DEUX SOURCES D’ALIMENTATION EN PARALLÈLE. 

MISE EN GARDE :

 NE PEUT ÊTRE UTILISÉ AVEC DES SPAS INDÉPENDANTS. 

Spécifications 

Longueur : 

4,55 po (115 mm) 

Largeur : 

2,650 po (67 mm) 

Type de boîtier :  Métal peint 
Électriques : 

Entrée – 14 V CA 

 

Sortie – 12 V CC 

 

Intensité du courant – 3 A max 

 

Puissance – 36 W 

 

Fréquence – 60 Hz 

 

(Utilisez seulement les raccords fournis par Hayward et un cordon d’une longueur maximale de 100 pi [10 m] jusqu’à la 
cascade d’eau.) 
 

NOTE : 

PEUT ÊTRE UTILISÉ DANS LES EMPLACEMENTS MOUILLÉS

 

 

 

Contient  

 

1  module de synchronisation (WFCLSYNC) 

 

1  diviseur à trois voies (WFXSPT3) 

 

1  guide d’utilisation  

 

Installation 

-

 

Le module de synchronisation comprend un cordon d’alimentation de 4 pi 
(1,2 m). 

-

 

La 

figure 1

 montre le câblage entre le transformateur Hayward et le 

module de synchronisation. 

Figure 1 

Summary of Contents for ColorLogic WFCLSYNC

Page 1: ...EATH WARNING THIS PRODUCT SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED PROFESSIONAL CAUTION RISK OF ELECTRICAL SHOCK NOT TO BE INSTALLED WITHIN 10 FEET 3 METERS FOR CANADIAN INSTALLATIONS OF R...

Page 2: ...nc Module WFCLSYNC 1 3 Way Splitter WFXSPT3 1 User Instruction Installation Sync Module includes a 4 foot long power cable Figure 1 shows wiring from Hayward transformer to Sync Module Connect and loc...

Page 3: ...ht Show Programming 1 Voodoo Lounge 2 Deep Blue Sea 3 Royal Blue 4 Afternoon Skies 5 Aqua Green 6 Emerald 7 Cloud White 8 Warm Red 9 Flamingo 10 Vivid Violet 11 Sangria 12 Twilight 13 Tranquility 14 G...

Page 4: ...AVANT DE PROC DER L INSTALLATION OU LA R PARATION DE CET QUIPEMENT LECTRIQUE COUPEZ LE COURANT AVERTISSEMENT LISEZ ET SUIVEZ TOUTES LES DIRECTIVES PR SENT ES DANS CE GUIDE D UTILISATION AINSI QUE CELL...

Page 5: ...OL AVERTISSEMENT NE RACCORDEZ PAS DEUX OU PLUS DE DEUX SOURCES D ALIMENTATION EN PARALL LE MISE EN GARDE NE PEUT TRE UTILIS AVEC DES SPAS IND PENDANTS Sp cifications Longueur 4 55 po 115 mm Largeur 2...

Page 6: ...de la position On la position Off et de nouveau la position On entre 2 10 secondes Dans le cas d un nouveau module de synchronisation une synchronisation entre la cascade d eau et les lumi res de la p...

Page 7: ...idement Mettez sous tension le transformateur en pla ant l interrupteur On durant 1 minute avant la synchronisation Coupez le courant au transformateur en pla ant l interrupteur Off et attendez 14 sec...

Reviews: