39
AUX Equip.
Inactive
Is LED
illuminated?
YES
NO
Verify 20-25VDC
on low voltage
side of relay
Inspect display,
verify the AUX
LED is ON
Put the system in
service mode &
press AUX button
NO
Replace local
display
(
see pg. 17
)
Is LED
illuminated?
YES
Automation is
preventing
manual turn-on
Is the
equipment
running?
YES
Section B
Go To
Section B
NO
Is voltage
present?
NO
Is AUX plugged
into correct
relay socket?
YES
Replace main
board
(
see pg. 17
)
Inspect for
interlocks & call
tech support
(908) 355.7995
YES
Relay line
power present?
(120/240VAC)
YES
Load power
present?
(120/240VAC)
NO
Correct
source power
issue
YES
Problem resides
in the wiring or
equipment
NO
Replace AUX
relay
(
GLX-RELAY
)
7. Auxiliary Equipment Inactive