28
Chlor. Off
High Salt/Amps
Is salt level
3400 or
below?
YES
NO
Reset
Chlorinator
diagnostics
Is voltage
reading above
35V?
YES
Verify correct
TCELL type in
configuration
4. Chlorinator OFF, High Salt/Amps
Test salt
level
Dilute salt level
and reset
average salt
Replace main
board
(
see pg. 17
)
NO
Does cell model
match
programming?
Change programming
to match installed
cell model
Reset average
salt, is error still
present?
Contact tech
support
(908)355.7995
YES
NO
Problem
solved
YES
NO