Gallons and (Liters) of Pool/Spa water

12,000 14,000 16,000 18,000

Current salt 

level

(45000) (52,500) (60,000) (67,500)

ppm

0

320    

(145)

373   

(170)

427   

(194)

480   

(218)

200

300   

(136)

350   

(159)

400   

(182)

450   

(205)

400

280   

(127)

327  

(148)

373   

(170)

420   

(191)

600

260   

(118)

303  

(138)

347    

(158)

390   

(177)

800

240   

(109)

280   

(127)

320   

(145)

360    

(164)

1000

220   

(100)

257   

(117)

293   

(133)

330   

(150)

1200

200   

(91)

233   

(106)

267   

(121)

300   

(136)

1400

180   

(82)

210   

(95)

240   

(109)

(123)

1600

160     

(73)

187   

(85)

213   

(97)

240   

(109)

1800

140     

(64)

163     

(74)

187     

(85)

210   

(95)

2000

120     

100     

80     

60     

20     

40     

(55)

(45)

(36)

(27)

(9)

(18)

140     

117     

23     

47    

(64)

(53)

(11)

(21)

160     

133     

27     

53     

(73)

(61)

(12)

(24)

180     

150     

30     

60    

(82)

(68)

(14)

(27)

(32)

80     

(36)

90     

(41)

93     

(42)

107     

(48)

120     

(55)

2200

3000

2800

2400

3200

Ideal

Ideal

Ideal

Ideal

2600

3400

OK

OK

OK

OK

OK

OK

OK

POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM

3600+

Dilute

Dilute

Dilute

Dilute

10,000

 8,000

 6,000

(37,500)

213

    

160

    

267    

(97)

(73)

(121)

200   

150   

250   

(91)

(69)

(114)

187   

140   

233   

(85)

(64)

(106)

173   

130   

217   

(79)

(59)

(98)

160   

120   

200   

(73)

(55)

(91)

147   

110   

183   

(67)

(51)

(83)

133   

100   

167   

(61)

(46

(76)

120   

90   

150   

(55)

(41)

(68)

107     

80     

133     

(48)

(36)

(61)

93     

70     

117     

(42)

(32)

(53)

80     

60     

100     

67     

50     

83     

53     

40     

67     

40    

30    

50     

13     

10     

17     

27     

20     

33     

(36)

(27)

(45)

(30)

(23)

(38)

(24)

(18)

(30)

(18)

(14)

(23)

(6)

(4)

(8)

(12)

(9)

(15)

Ideal

Ideal

Ideal

Dilute

Dilute

Dilute

(30,000)

(22,500)

7

Servicing and Cleaning the Aqua Trol cell

Turn off power to the Aqua Trol before removing the electrolytic cell.  Once removed,

look inside the cell and inspect for scale formation (light colored crusty or flaky

deposits) on the plates and for any debris which has passed through the filter and

caught on the plates.  If no deposits are visible, reinstall.  If deposits are seen, use a

high pressure garden hose and try to flush the scale off.  If this is not successful, use

a plastic or wood tool (do not use metal as this will scratch the coating off the plates)

and scrape deposits off of the plates.  Note that a buildup on the cell indicates that

there is an unusually high calcium level in the pool (old pool water is usually the

cause).  If this is not corrected, you can expect to have to periodically clean the cell.

The simplest way to avoid this is to bring the pool chemistry to the recommended

levels as specified.

Mild Acid Washing: 

 Use only in severe cases where flushing and scraping will not

remove the majority of deposits.  To acid wash, turn off power to Aqua Trol.  Remove

cell from piping.  In a clean plastic container, mix a 4:1 solution of water to muriatic acid

(one gallon of water to one quart of muriatic acid).  ALWAYS POUR ACID INTO

WATER - NEVER POUR WATER INTO ACID.  Be sure to wear rubber gloves and

appropriate eye protection.  The level of the solution in the container should just

reach the top of the cell so that the wire harness compartment is NOT submerged.  It

may be helpful to coil the wiring before immersing the cell.  The cell should soak for a

few minutes and then rinse with a high pressure garden hose. If any deposits are still

visible, repeat soaking and rinsing.  Replace cell and inspect again periodically.

Winterizing

The Aqua Trol electrolytic cell

 

will be damaged by freezing water just as your pool

plumbing would.  In areas of the country which experience severe or extended periods

of freezing temperatures, be sure to drain all water from the pump, filter, and supply

and return lines before any freezing conditions occur.  The electronic control is ca-

pable of withstanding any winter weather and should not be removed.

Spring Start-up

DO NOT turn the Aqua Trol on, until the pool water chemistry has been brought to

the proper levels.  This information can be found on page 2.

Summary of Contents for Aqua Trol AQ-TROL-RJ-CUL

Page 1: ...Too high add muriatic acid Alkalinity 80 120 ppm Salt 2700 3400 ppm Add salt as required to increase Add baking soda to increase Stabilizer 20 30 ppm Add cyanuric acid to increase Calcium 125 250 ppm...

Page 2: ...uired for warranty service If written proof of purchase is not provided the manufacturing date code will be the sole determinant of the date of installation of the product To obtain warranty service o...

Page 3: ...g to chart on page 4 5 HighSalt LEDilluminated Check salt level in pool spa If salt level is too high lower salt level by draining some of the pool water out of the pool and replace with fresh water C...

Page 4: ...d especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water Dry acid can cause a buildup of by products that can damage your chlorina...

Page 5: ...easurements Insert values of pH Ti Ci and Ai into the above equation If Si equals 2 or more scaling and staining may occur If Si equals 2 or less corrosion or irritation may occur Si pH Ti Ci Ai 12 1...

Page 6: ...om of the pool Run the filter pump for 24 hours with the suction coming from the main drain use the pool vacuum if there is not main drain to allow the salt to evenly disperse throughout the pool The...

Page 7: ...sful use a plastic or wood tool do not use metal as this will scratch the coating off the plates and scrape deposits off of the plates Note that a buildup on the cell indicates that there is an unusua...

Page 8: ...fficiency In areas where water is hard high mineral content and in pools where the water chemistry has been allowed to get out of balance the cell may require periodic cleaning The Inspect Cell LED wi...

Reviews: