Water Chemistry

As with any pool, it is important that you maintain chemical makeup of the pool water.

The table on page 2 summarizes the levels that are recommended by the National Spa

and Pool Institute (NSPI).  The only special requirement for the Aqua Trol is the salt

level and stabilizer.  It is important to maintain these levels in order to prevent corro-

sion or scaling and to ensure maximum enjoyment of the pool.  Test your water

periodically.  Your local pool store can provide you with the chemicals and proce-

dures to adjust the water chemistry.  Be sure to tell the pool store that you are using

an Aqua Trol

 

chlorine generator.

Saturation index

The saturation index (Si) relates to the calcium and alkalinity in the water and is an

indicator of the pool water "balance".  Your water is properly balanced if the Si is 0 ±.2.

If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved

into the water.  If the Si is above +0.2, scaling and staining will occur.  Use the equation

and chart below to determine the saturation index.

2

ºC       ºF       

 

Ti

Calcuim

Hardness

Ci

Total

Alkalinity

Ai

53

60

66

76

84

94

103

12

16

19

24

29

34

39

.3

.4

.5

.6

.7

.8

.9

How to use: 

Measure pool pH, temperature, calcium hardness,

and total alkalinity.  Use the chart above to determine Ti, Ci,and

Ai from your measurements.  Insert values of pH, Ti, Ci and Ai
into the above equation.  If Si equals .2 or more, scaling and 

staining may occur.  If Si equals -.2 or less corrosion or irritation

may occur. 

Si = pH + Ti + Ci + Ai - 12.1

-.2

0

.2

CORROSIVE

SCALING

75

75

100

100

125

125

150

150

200

200

250

250

300

300

400

400

600

600

800

800

1.5

1.9

1.6

2.0

1.7

2.1

1.8

2.2

1.9

2.3

2.0

2.4

2.1

2.5

2.2

2.6

2.4

2.8

2.5

2.9

OK

9

FROM

FILTER

RETURN

JET

Plumbing

Unscrew the hose adaptor from the pool return jet fitting and, in its place, screw in the

right-angle cell mounting adaptor.  Note that this installation does NOT require a flow

switch--however it is very important that the cell be mounted vertically directly below

the return jet in order to allow the gases produced in the cell to naturally dissipate in

the pool.  Attach the cell to the union and then use the fittings supplied to attach  the

lower end of the cell to either the hose or rigid PVC pipe coming from the pools

filtration system.  Tighten all union nuts 

BY HAND

 for a watertight seal.

Wiring

Power must be shut off at the circuit breaker before performing any wiring.  Be sure to

follow Local and NEC/CEC electrical codes.  The Aqua Trol has been designed to

easily wire into typical above ground pool systems.  To provide safe operation, the

Aqua Trol must be properly grounded and bonded.

Input Power

The standard 120 VAC line cord should be plugged into a GFCI receptacle.  See

diagram below.

SUBPANEL

GROUND

NEUTRAL

GFCI

OUTLET

AQUA TROL

(AQ-TROL-RJ-CUL)

Aqua Trol

Summary of Contents for Aqua Trol AQ-TROL-RJ-CUL

Page 1: ...Too high add muriatic acid Alkalinity 80 120 ppm Salt 2700 3400 ppm Add salt as required to increase Add baking soda to increase Stabilizer 20 30 ppm Add cyanuric acid to increase Calcium 125 250 ppm...

Page 2: ...uired for warranty service If written proof of purchase is not provided the manufacturing date code will be the sole determinant of the date of installation of the product To obtain warranty service o...

Page 3: ...g to chart on page 4 5 HighSalt LEDilluminated Check salt level in pool spa If salt level is too high lower salt level by draining some of the pool water out of the pool and replace with fresh water C...

Page 4: ...d especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water Dry acid can cause a buildup of by products that can damage your chlorina...

Page 5: ...easurements Insert values of pH Ti Ci and Ai into the above equation If Si equals 2 or more scaling and staining may occur If Si equals 2 or less corrosion or irritation may occur Si pH Ti Ci Ai 12 1...

Page 6: ...om of the pool Run the filter pump for 24 hours with the suction coming from the main drain use the pool vacuum if there is not main drain to allow the salt to evenly disperse throughout the pool The...

Page 7: ...sful use a plastic or wood tool do not use metal as this will scratch the coating off the plates and scrape deposits off of the plates Note that a buildup on the cell indicates that there is an unusua...

Page 8: ...fficiency In areas where water is hard high mineral content and in pools where the water chemistry has been allowed to get out of balance the cell may require periodic cleaning The Inspect Cell LED wi...

Reviews: