9
8
INSTALLATION
Step 4
Connecting to skimmer:
Connect the skimmer cone adapter to
tapered male end of the first hose section.
Note: Hose end goes into cone adapter.
Step 5
Check the water flow reading on
the flow gauge.
The black disk should be between
the “MIN” and “MAX” markings.
If the disk is in the proper location,
move on to step 6.
If the black disk is outside of the box on the “MAX” side and you
have connected your hose to the skimmer, reduce the vacuum/
water flow by using one of the following:
• Suction valve(s) in the filter system (if equipped with)
• Hayward regulator valve
FIRST HOSE SECTION
CONE
ADAPTER
REGULATOR
VALVE
CONE ADAPTER
TO MAIN DRAIN
(if applicable)
TO PUMP
To install the Hayward regulator valve:
1. Remove the hose from the skimmer cone adapter.
2. Close the regulator valve by rotating the blue collar clockwise
until tight.
3. Insert the regulator valve onto the skimmer cone adapter and the
hose end into the regulator valve.
4. Turn the filter system on and allow it to evacuate any air in
the system.
5. Turn the blue collar clockwise until black disk appears between
“MIN” and “MAX” markings.
Reading Too High?