background image

* MUST BE USED IN CONJUNCTION WITH

  24VAC TRANSFORMER AND SOLENOID

 PANEL CUT-OUT 

REF "24VAC IN"

.813

1.625

3.250

.563

1.125

Ø .177 2X

R .312 4X

APPROVED:

DRAWN:

PART NUMBER

SCALE:

SHEET

OF

REVISION

DRAWING TYPE:

SIZE:   A

BY:

ECN NO.

PA

GE

DATE:

DATE:

ECN:

REVISED PER

CHK'D.:

PAGE

         Haws Corporation - All Rights Reserved. HAWS   and other trademarks used in these materials are the exclusive property of Haws Corporation.

C

R

MODEL(S)

1455 KLEPPE LANE

SPARKS, NEVADA  89431

(775) 359-4712  FAX (775) 359-7424

E-MAIL:  [email protected]
WEBSITE: WWW.HAWSCO.COM

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS

MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

G. EXLINE

05/10/94

2

0002080407.D

VRKHO1

N/A

1

1

FV

08/14/20

1370

SLS

4 of 

4

INSTALLATION

5568

4 o
f 4

2020

FV

OLD VERSION

CURRENT VERSION

REMOVE

BEZEL NUT TO

ALLOW ACCESS

SCREWS ON

EITHER SIDE

SECURE SENSOR

HO SENSOR CAN BE MOUNTED IN
EITHER APPLICATION SHOWN BELOW

(PANEL NOT SHOWN)

Summary of Contents for VRKHO1

Page 1: ... Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general special or cons...

Page 2: ...icates the sensor is in start up mode If the red light is flashing this indicates that the sensor is picking up an object Unless this object is a permanent fixture i e a wall a plant etc it must be removed from the view of the sensor The sensor will adapt itself around such permanent fixtures In this mode the sensor will take up to ten 10 minutes to calibrate NOTE 1 If the 24VAC power supply is in...

Page 3: ...zero solenoid coil is at fault Coils may be easily replaced without disconnecting valve body from plumbing Replace with new 24VAC rated coil Step 4 Check wiring harness If wiring harness appears to be hooked up correctly disconnect harness from valve sensor and power cord then check harness for continuity using Ohm meter Resistance between connectors attached to each other by wires should be near ...

Page 4: ...aws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE G EXLINE 05 10 94 2 0002080407 D VRKHO1 N A 1 1 FV 08 14 20 1370 SLS 4 of 4 INSTALLATION 5568 4 of 4 ...

Reviews: