Haws VRKHO1 Installation, Operation & Maintenance Instructions Download Page 2

07/20 

      Model VRKHO1 

Page 2 of 4 

 

 
 
 
 
 
 
 

 

 
 

 

 
 

Recommended Tools: 

5/64” Hex Key wrench, 11/32” socket wrench or open-end wrench. 

 

INSTALLATION PROCEDURE 

 

Step 1: 

Remove grille, shut off water supply and disconnect power from 24VAC transformer.

 

 

Step 2: 

Remove bottom plate from fountain using 5/64” Hex key wrench. 

 

Step 3: 

Remove sensor to be replaced using 11/32” socket wrench and disconnect leads to sensor. 

*

 With older style 24VAC H.O. sensor, unplug sensor from cable assembly. Snip off the 3 

position connect from cable assembly and tape off or, with a wire nut, insulate the white wire 
(this wire, neutral, is not required with new style sensor.) 

 

Step 4: 

Conne

ct leads from cable assembly to sensor. Black lead to “24VAC IN” and red lead to “TO 

VALVE”. 

 

Step 5: 

Install sensor. 

 

Step 6: 

Reconnect power to the 24VAC transformer. 

This will initiate the sensor’s “start-up mode”. 

“Start-up mode” for the H.O. sensor will take approximately five (5) minutes to complete its 
full cycle of self-calibration. It is important that no object is in front of sensor during this time. 
A steady red light visible in the center of the sensor window indicates the sen

sor is in “start-

up 

mode”. If the red light is flashing, this indicates that the sensor is picking up an object. 

Unless this object is a permanent fixture, (i.e. a wall, a plant, etc.), it must be removed from 
the view of the sensor. The sensor will adapt itself around such permanent fixtures. In this 
mode, the sensor will take up to ten (10) minutes to calibrate. 

 

 

NOTE: 

 

1. 

If the 24VAC power supply is interrupted for more than fifteen (15) seconds, the “start-up 
mode” will automatically repeat itself when power is restored. 

 

2. 

If the indicator light flashes three (3) times quickly, then three (3) times slowly and 
continues to repeat this sequence, this indicates incorrect wiring or a short in the 24VAC 
power supply. 

 

3. 

When someone remains standing in front of the sensor for more than thirty (30) seconds, 
the sensor will automatically shut off the water supply to the bubbler. To restart, stand to 
the side for a moment, then return to a position in front of the sensor. 

 

Step 7: 

Turn water supply on and adjust the 

bubbler’s flow using the black regulator mounted next to 

the solenoid valve. Finally, check fountain for leaks. Verify the chiller turns off after water 
reaches proper temperature. If there are any problems, refer to sensor’s Troubleshooting 
Guide. 

 

Step 8: 

Re-install bottom plate and grille. 

 

 

Summary of Contents for VRKHO1

Page 1: ... Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general special or cons...

Page 2: ...icates the sensor is in start up mode If the red light is flashing this indicates that the sensor is picking up an object Unless this object is a permanent fixture i e a wall a plant etc it must be removed from the view of the sensor The sensor will adapt itself around such permanent fixtures In this mode the sensor will take up to ten 10 minutes to calibrate NOTE 1 If the 24VAC power supply is in...

Page 3: ...zero solenoid coil is at fault Coils may be easily replaced without disconnecting valve body from plumbing Replace with new 24VAC rated coil Step 4 Check wiring harness If wiring harness appears to be hooked up correctly disconnect harness from valve sensor and power cord then check harness for continuity using Ohm meter Resistance between connectors attached to each other by wires should be near ...

Page 4: ...aws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE G EXLINE 05 10 94 2 0002080407 D VRKHO1 N A 1 1 FV 08 14 20 1370 SLS 4 of 4 INSTALLATION 5568 4 of 4 ...