Haws 7501BL Installation, Operation & Maintenance Instructions Manual Download Page 4

09/16 

7501BL/7501BL240     

Page 4 of 5 

 

 
STEP 5:

  Fold side flaps to over sides of tank, using the Velcro to attach the edges together. 

 

 

STEP 6: 

Pull open/down eyewash flap and yellow eyewash arm. Attach webbing loop around 
eyewash arm below eyewash heads.  

 

       

 

 

STEP 7: 

  Mount assembled eyewash and blanket in accordance with 7501/7501T/7501T240 

installation instructions. 

 

NOTICE: ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC CODE 

USING TYPE 3R COMPLIANT EQUIPMENT. MODEL 7501T240 IS TYPE 4 
COMPLIANT IF TYPE 4 COMPLAINT EQUIPMENT IS USED.  

 

OPERATION AND TEST INSTRUCTIONS 

 
Test weekly.  Instruct all employees in the use of this emergency eyewash. Personnel should be 
assigned to check liquid level daily. 

 

STEP 1: 

Lead patient to nearest eyewash station.  Seconds can make the difference in 
preventing serious eye injury. 

STEP 2: 

Pull yellow eyewash arm firmly. Eyewash arm will drop to activate eyewash. 

STEP 3: 

Lower head until eyes enter eyewash stream. Use thumbs and forefingers to hold 
eyelids open.  Flush for 15 minutes. 

STEP 4:  

Seek qualified medical attention immediately 

 

For more information on Haws products, see our website: 

www.hawsco.com

 

 
© 2016 Haws

®

 Corporation – All Rights Reserved 

Reviews: